| Plan Review Notes For Permit 02050463 |
| Permit Number |
02050463 |
|
| Review Stop |
B |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2002-12-27 00:00:00 | CHECKLIST: | | | 1-PERMIT #02050463 IS FOR WORK AT MAIN | | | HOUSE. THIS GAZEBO IS COMPLETE NEW | | | CONSTRUCTION. THEREFORE, A SEPARATE | | | PERMIT AND SEPARATE REVIEWS BY ZONING | | | AND BUILDING ARE REQUIRED. | | | APPLY FOR A SEPARATE PERMIT. | | | | | | **NOTES: | | | A) ARCHITECT TO PROVIDE ALL INFORMATION | | | REQUIRED BY SECTION 1606.1.7 OF FBC | | | 2001. | | | B) PLANS SUBMITTED ARE VERY INCOMPLETE. | | | MISSING BEAMS, TRUSS CONNECTORS, | | | ANCHOR BOLTS FOR COLUMNS TOP PLATE, | | | CALCULATED UPLIFT LOADS FOR ROOF AND | | | COLUMNS, SIZE OF COL. BOTT. PLATE. | | | C) CLARIFY FOOTING SIZES FOR COLUMNS AND | | | CONCRETE SLAB EDGES. | | | D)ARCHITECT TO PROVIDE ALL HIS INFORMA- | | | TION AS REQUIRED BY CHAPTER 481 OF | | | FLORIDA STATUTES WHEN SUBMITTING | | | DOCUMENTS FOR PUBLIC RECORDS. | | | | | | | | | *************** REMAINDER ************* | | | | | | PROVIDE INFORMATION REQUESTED ON PROVISO | | | DATED 6-22-02 TO AVOID ANY DELAYS OR | | | CONFLICTS TO OBTAIN THE FINAL C.O. |
|