| Plan Review Notes For Permit 02050254 |
| Permit Number |
02050254 |
|
| Review Stop |
R |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2002-08-02 00:00:00 | APPROVED WITH PROVISO: | | | 1-FLOOD ZONE AO. NEED TO PROVIDE THE | | | ELEVATION CERTIFICATE. | | | 2-PROVIDE COMPLETE AND REVISED INFO. FOR | | | STORM SHUTTERS UNDER A SEPARATE PERMIT | | | 3-PROVIDE SOIL TEST REPORT SIGNED AND | | | SEALED BY THE ENG'R. CH. 471 FL. ST. | | | 4-PRODUCT APPROVALS: | | | A)WINDOW MULLIONS: | | | *NEED PRODUCT APPROVAL FORM SIGNED AND | | | SEALED BY ENGINEER AND ARCHITECT AS | | | DONE WITH THE OTHER PRODUCT APPROVALS | | | SUBMITTED. | | | *CLEARLY INDICATE ALL COMPONENTS THAT | | | APPLY TO THIS PROJECT. | | | *MULLION NEED TO TRANSFER THE LOAD | | | DIRECTLY TO THE ROUGH OPENING | | | SUBSTRATE TO COMPLY WITH SECTION | | | 1707.4.5.2 FBC 2001. REVISE DWG. | | | B)SINGLE HUNG WINDOWS DON'T MEET THE | | | DESIGN PRESSURES CALCULATED BY THE | | | ARCHITECT. NEED ANOTHER PROD. APPROVAL | | | 5-REVISE SURVEY. NEED LOT 8 W/ BAY WIND. | | | | | | NOTES: | | | -DWGS AND COMMENTS TO BE FILED UNDER | | | PERMIT #02050254. | | | -THESE COMMENTS ALSO APPLY TO PERMIT | | | #02050256. |
|