| Plan Review Notes For Permit 02050144 |
| Permit Number |
02050144 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2002-06-03 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | | | | 1) SHT A1-1 ROOM #332, SHOWER BATHROOM | | | SHALL BE ADAPTABLE. 11-4.1.3(11) PLEASE | | | PROVIDE DETAILS. | | | 2) SHT A1-1 SEPARATE TENANTS, PLEASE | | | PROVIDE MINIMUM FACILITIES CALCULATIONS | | | FOR EACH TENANT SPACE. PROVIDE SQUARE | | | FOOTAGE FOR EACH SPACE SO FIXTURES CAN | | | BE CALCULATED. DRINKING FOUNTAINS AND | | | SERVICE SINKS REQUIRED ECT. | | | 3) SHT A2-1 DETAILS #7 RM #312 & #16 RM | | | #345 SINKS SHALL COMPLY WITH 11-4.24 AND | | | ALL SUBSECTIONS. | | | 4) SHT A1-1 TOILET ROOM #314, DOOR SHALL | | | NOT OPEN INTO THE CLEAR FLOOR SPACE OF | | | ANY FIXTURE. 11-2.22.2 | | | 5) SHT P1-3 FLOOR DRAIN AT WATER HEATER | | | NOT APPROVED. ALL INDIRECT WASTE SHALL | | | DRAIN INTO A FLOOR SINK. SEC 802.3 | | | 6) SHT P2-1 MANUFACTURE INFORMATION RE- | | | QUIRED FOR THE POINT OF USE WATER HEATER | | | FOR LISTING BY APPROVED AGENCY. | | | 7) SHT P2-1 MANUFACTURE INFORMATION RE- | | | QUIRED FOR FILTER. MUST BE NSF APPROVED. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|