| Date |
Text |
| 2002-05-21 00:00:00 | CHECKLIST: |
| | 1-NEED RECORDED NOTICE OF COMMENCEMENT. |
| | 2-AFTER ORIGINAL DRAWINGS ARE CORRECTED |
| | BRING THEM TO PALM BEACH COUNTY TO PAY |
| | THE IMPACT FEES. BRING BACK STAMPED |
| | DRAWINGS AND PAID RECEIPT. |
| | 3-REVISE STRUCTURAL GABLE END DETAIL TO |
| | COMPLY WITH SECTION 2117 FBC 2001. |
| | (CONTINUOUS WALL). |
| | 4-CONCRETE SLAB: SPECIFY JOINTS AS REQ'D |
| | BY SECTION 1909.3 FBC 2001. |
| | 5-PERCENTAGE OF EXTERIOR OPENINGS AT |
| | ADDITION EXCEEDS THE PERCENTAGE THAT |
| | IS ALLOWED BY TABLE 600 FBC 2001. |
| | REVISE WEST ELEVATION AS REQUIRED. |
| | 6-PROVIDE DETAILS/SPECS FOR ATTACHMENT |
| | OF NEW ROOF TO EXISTING ONE. SECTION |
| | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
| | 7-SPECIFY FIREBLOCKING AS REQUIRED BY |
| | SECTION 705.3.1.3 FBC 2001. |
| | 8-UPDATE PLANS AND NOTES TO FBC 2001. |
| | SEE COMMENTS ON PLANS AND PLEASE |
| | RETURN REVIEWED SET AFTER CORRECTIONS |
| | ARE DONE TO THE ORIGINAL DRAWINGS TO |
| | EXPEDITE THE REVIEW PROCESS. |
| | 9-FOOTING F1 IS 16" DEEP. FBC 2001 SEC. |
| | 1804.1.3 REQUIRES 12" MIN BELOW FINISH |
| | GRADE. CLARIFY HOW IS THIS ACHIEVED IF |
| | CONCRETE SLAB IS +/- 12" ABOVE GRADE. |
| | 10-PROVIDE DOORS AND WINDOWS COMPLETE |
| | BUCK DETAIL. SEE SEC. 1707.4.4.2 FBC |
| | 2001 FOR BUCK REQUIREMENTS. |
| | 11-PROVIDE PRODUCT APPROVAL FOR: |
| | A)FRENCH DOORS WITH LEGIBLE DRAWINGS. |
| | B)SINGLE HUNG WINDOWS WITH LEGIBLE DWGS. |
| | |
| | 12-STORM SHUTTERS: |
| | A)NEED PRODUCT APPROVAL W/ LEGIBLE DWGS. |
| | B)CLEARLY INDICATE ON DRAWINGS SPECIFIC |
| | MOUNTING CONDITIONS TO BE USED. |
| | PROVIDE KEY PLAN AND ANCHOR SCHEDULE |
| | INDICATING ANCHOR TYPE AND SPACING TO |
| | BE USED. SEE ATTACHED SAMPLE. |
| | 13-OWNER/AGENT TO SIGN AND DATE BOTTOM |
| | FORM OF ENERGY CALCULATIONS. |
| | 14-OWES $332.69 FOR UPDATE CONSTRUCTION |
| | VALUE AND RADON FEES. |
| | 15-ENGINEER OF RECORD TO HAVE ALL HIS |
| | INFORMATION IN ALL DRAWINGS AS REQ'D |
| | BY CHAPTER 471 FLORIDA STATUTES WHEN |
| | SUBMITTING DOCUMENTS FOR PUBLIC RECORD |