| 2002-05-04 00:00:00 | DENIED | | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | | | 1) PLEASE ADJUST YOUR NOTES, DETAILS, OR | | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | | FORMATION REQUIRED FOR PLAN REVIEW | | | 2) | | | FBC-2001 SEC 424.2.6.6.5 WHERE PROVIDED, | | | THE VACUUM OR PRESSURE CLEANER FITTING | | | SHALL BE LOCATED AT LEAST 6" AND NOT | | | GREATER THAN 12" BELOW THE MINIMUM OPER- | | | ATING WATER LEVEL OR AS AN ATTACHMENT TO | | | THE SKIMMER. | | | 3) | | | FBC-2001 SEC 424.2.7.1 POOL CIRCULATING | | | PUMPS SHALL BE EQUIPPED ON THE INLET | | | SIDE WITH AN APPROVED TYPE HAIR AND LINT | | | STRAINER WHEN USED WITH A PRESSURE FIL- | | | TER. (DETAIL) | | | 4) | | | MAIN DRAIN DETAIL - SHOW 1'0" MAX TO TIE | | | IN FOR VENT. | | | 5) | | | VENT DETAIL - LABEL VENT "POOL SAFETY | | | DEVICE - DO NOT HANDLE" | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|