| Date |
Text |
| 2002-06-03 00:00:00 | BEFORE A PERMIT TO CONSTRUCT MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO THE |
| | COUNTY FOR THE CITY, THE PERMIT PLANS |
| | STAMPED BY THAT OFFICE AND A COPY OF |
| | THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION.CALL 233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | PROVIDE A DETAIL FOR THE STAIR |
| | HANDRAILS SEE FBC 1007.5 |
| | |
| | SHOW A DETAIL AND/OR NOTE FOR THE |
| | EMERGENCY ESCAPE/RESCUE OPENINGS |
| | (WINDOWS) FOR THE SLEEPING ROOMS.SEE |
| | FBC 1005.4. |
| | |
| | THE WINDOWS SHOWN ON THE EAST ELEVATION, |
| | SHEET A4 DO NOT AGREE WITH THE FLOOR |
| | PLAN, SHEET A2.REVISE AS NECESSARY. |
| | |
| | SHEET A2 AND S2 DO NOT AGREE AS TO THE |
| | LAYOUT OF THE SECOND FLOOR BALCONY. |
| | SHOW A GUARDRAIL, FBC 1015. |
| | |
| | PROVIDE A STAIR CONSTRUCTION DETAIL, |
| | INCLUDING THE LANDINGS. SEE FBC 1007. |
| | |
| | SHOW THE METHOD OF ATTIC ACCESS, SEE |
| | FBC 2309.6. |
| | |
| | SHOW A CONNECTION DETAIL FOR THE PATIO |
| | ROOF FRAMING TO THE LEDGER AND THE BEAM. |
| | |
| | SHOW DIMESIONS TO LOCATE THE COLUMNS IN |
| | THE WALL BETWEEN THE HOUSE AND GARAGE. |
| | |
| | WHAT ARE THE THREE 3" COLUMNS IN FRONT |
| | OF THE GARAGE FOR? |
| | |
| | PROVIDE A DOOR AND WINDOWD SCHEDULE. |
| | |
| | SHOW SAFETY GLAZING IN THE WINDOWS AND |
| | DOORS FOR THE REAR PATIO.SEE FBC |
| | 2405.2. |
| | |
| | SHOW A HEADER DETAIL FOR THE FRAME |
| | OPENING DEPICTED IN 4/S2. |
| | |
| | SHEET S4, PLEASE PROVIDE A MORE |
| | CONTEMPORARY ROOF TRUSS LAYOUT. |
| | |
| | PROVIDE TWO SETS OF LEGIBLE PRODUCT |
| | APPROVALS FOR THE DOORS, WINDOWS AND |
| | ROOR COVERING.ALTERNATIVELY, A |
| | SEPARATE PERMIT AND FEES WILL BE |
| | REQUIRED IF THE INFORMATION IS NOT |
| | INCLUDED WITH THIS PERMIT APPLICATION. |