| Plan Review Notes For Permit 02040697 |
| Permit Number |
02040697 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2002-04-17 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT 02040697 | | | 4812 S DIXIE | | | CONT: J.P. HURBON, INC. | | | 575-2461 | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | OCCUPANCY= A2 SMALL ASSEMBLY | | | 40'X48'= 1920 S F @ 15 F/PER=128 OCC. | | | | | | 1)- FL BLD CODE 104.2.1.2 ADDITIONAL | | | INFORMATION, A SEATING PLAN WITH ISLE | | | WIDTHS AND DESIGNATE EGRESS DOORS. | | | 2)- FRONT ENTRY DOOR SWING NOT INDICATED | | | FL BLD CODE 1012.1.2 EGRESS DOORS SHALL | | | BE SIDE SWINGING AND (1) WHEN SERVING AN | | | OCCUPANT LOAD OF 50 OR MORE THAN IT | | | SHALL SWING IN THE DIRECTION OF EGRESS. | | | 3)- FL BLD CODE 1012.1.3 THE ELEVATION | | | OF SURFACES ON BOTH SIDES OF A DOORWAY | | | SHALL NOT VARY MORE THAN 1/2".THE ELEVA- | | | TION SHALL BE MAINTAINED ON BOTH SIDES | | | OF THE DOORWAY FOR A DISTANCE AT LEAST | | | EQUAL TO THE WIDTH OF THE WIDEST LEAF.4) | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561)659-8096X8412 |
|