| Date |
Text |
| 2002-07-15 00:00:00 | SECOND CHECKLIST: |
| | 1-PROVIDE COMPLETE DETAILS AND SPECS FOR |
| | STAIRS, RAILINGS AND GUARDRAILS. SEE |
| | SECTIONS 1007, 1015 & 1608.2 FBC 2001. |
| | **NOTE : INCLUDE RAILING AT SUNDECK. |
| | 2-SPIRAL STAIRS SHEET TO BE SIGNED, |
| | SEALED AND DATED BY THE ENGINEER OF |
| | HEDJ ENGINEERING WHEN SUBMITTING |
| | DOCUMENTS FOR PUBLIC RECORDS AS REQ'D |
| | BY CHAPTER 471 FLORIDA STATUTES. |
| | 3-PROVIDE ON PLANS THE MIN. STRUCTURAL |
| | INFORMATION REQUIRED BY SECTION |
| | 1606.1.7 FBC 2001. |
| | 4-CLARIFY EGRESS WINDOW #3 AT MASTER |
| | BEDROOM. EXTERIOR ELEVATION SHOWS A |
| | VERTICAL MULLION IN THE MIDDLE OF THE |
| | WINDOW. IF SO, THEN CLEAR OPENING DOES |
| | NOT COMPLY WITH SEC. 1005.4.4 FBC 2001 |
| | 5-DRAWINGS AND SPECIFICATIONS REFERENCE |
| | ARCHITECT AND ENGINEER THROUGHOUT. |
| | NEED ARCHITECT AND ENGINEER TO SIGN, |
| | SEAL, DATE AND PROVIDE ALL HIS/HER |
| | INFORMATION AS REQUIRED BY CHAPTER 471 |
| | FL. STATUTES WHEN SUBMITTING INFO. |
| | FOR PUBLIC RECORDS. |
| | 6-AREA CALCULATIONS ARE WRONG. REVISE. |
| | 7-PROVIDE COMPLETE SECTIONS, DETAILS & |
| | SPECIFICATIONS AT SUNDECK. SEE |
| | COMMENTS ON PLANS. |
| | 8-CLEARLY SPECIFY ATTIC VENTILATION AS |
| | REQUIRED BY SEC. 2309.6 FBC 2001. |
| | **NOTE: THERE IS A CONFLICT WITH THE |
| | BLOCKING SPECIFIED AND VENTILATION. |
| | SEE DETAIL 6 OF S-1. |
| | 9-IF GETTING CREDIT ON THE ENERGY CALCS |
| | FOR CEILING FANS, THEN, SPECIFIED SIZE |
| | AND NUMBER OF FANS REQUIRED BY TABLE |
| | 6-6 CHAPTER 13 FBC 2001. |
| | 10-PROVIDE PRODUCT APPROVAL FOR STORM |
| | SHUTTERS AND COMPLETE KEY PLAN AND |
| | INSTALLATION SCHEDULE. SEE CITY SAMPLE |
| | 11-PROVIDE COMPLETE FRAMING DETAILS FOR |
| | SKYLIGHT. SEC. 104.2.1.2 CITY |
| | AMENDMENTS TO FBC 2001. |
| | 12-PROVIDE SOIL TEST REPORT SIGNED AND |
| | SEALED BY THE RESPECTIVE ENGINEER. |
| | 13-DRAW GUARDRAIL DETAIL TO SCALE. |
| | RAILING DETAIL ON SHEET A-9 WON'T |
| | WORK FOR THE 4" MAX. SPHERE TO PASS |
| | THRU AS REQUIRED BY SEC. 1015 FBC 2001 |