Plan Review Notes
Plan Review Notes For Permit 02040506
Permit Number 02040506
Review Stop B
Sequence Number 1
Notes
Date Text
2002-05-17 00:00:00CHECKLIST:
 1-A)ARCHITECT TO SIGN, SEAL AND DATE
 ALL DWGS & PROVIDE ALL HIS INFORMATION
 (EG: LIC #, ETC) AS REQUIRED BY FL.
 STATUTES CHAPTER 481. NOTE: SPECS TOO
 B)ENGINEER TO SIGN, SEAL AND DATE ALL
 DWGS & PROVIDE ALL HIS INFORMATION AS
 REQ'D FL ST CHAPTER 471. (SPECS TOO)
 2-AFTER CORRECTIONS ARE DONE TO ALL
 ORIGINAL DRAWINGS TAKE THEM TO PALM
 BEACH COUNTY TO PAY THE IMPACT FEES.
 BRING BACK STAMPED DRAWINGS AND PAID
 RECEIPT.
 3-AREA CALCULATIONS ON DWG A-2 ARE WRONG
 SEE FLOOR PLANS AND REVISE AS REQUIRED
 TO PROPERLY ASSESS THE IMPACT, RADON
 AND VALUE FEES.
 4-PROVIDE COMPLETE DETAILS AND SPECS FOR
 STAIRS, RAILINGS AND GUARDRAILS. SEE
 SECTIONS 1007, 1015 & 1608.2 FBC 2001.
 **NOTE: INCLUDES RAILING AT SUNDECK.
 5-SPECIFY COMPLETE SIZE AND SPECS FOR
 SPIRAL STAIRS. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 6-CLEARLY SPECIFY WINDOWS TO BE REPLACED
 AND SPECIFY TYPE AND SIZE IN ORDER TO
 VERIFY FOR COMPLIANCE WITH EGRESS
 REQUIREMENTS SEC. 1OO5.4 FBC 2001.
 WINDOW SCHEDULE DON'T MATCH PLANS.
 7-PROVIDE ALL INFORMATION ON DRAWINGS AS
 REQUIRED ON SECTION 1606.1.7.
 8-NEW SUNDECK WAS THE ROOF ABOVE GARAGE.
 ENGINEER TO CERTIFY IF EXISTING FRAM'G
 WILL BE ABLE TO SUPPORT THE NEW LOADS
 OR IF REINFORCEMENT IS NECESSARY.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 9-PROVIDE ATTIC ACCESS AT 2ND FL. ROOF.
 SECTION 2309.6 FBC 2001.
 10-DRAW ALL EXTERIOR ELEVATIONS. SEE
 SEC. 104.3.1.1 CITY AMENDMENTS TO FBC.
 11-SPECIFY ATTIC VENTILATION. SEC 2309.7
 FBC 2001.
 **NOTE: SEE DETAIL 6 OF S-1 REGARDING
 THE BLOCKING TO AVOID A CONFLICT.
 12-UPDATE WINDOW AND DOOR BUCK DETAIL
 AND SPECS TO COMPLY WITH SECTION
 1707.4.4.2 FBC 2001.
 13-IF GETTING CREDIT ON THE ENERGY CALCS
 FOR CEILING FANS, THEN, SPECIFY SIZES
 AND LOCATIONS. SEE TABLE 6-6 CHAPTER
 13 FBC 2001.
 14-PROVIDE PRODUCT APPROVAL FOR:
 A)CASEMENT WINDOW PRODUCT APPROVAL DWGS
 ARE NOT LEGIBLE.
 B)STORM SHUTTERS WITH COMPLETE KEY PLAN
 AND INSTALLATION SCHEDULE SHOWING
 ANCHOR TYPE AND SPACING TO BE USED.
 C)SKYLIGHTS
 D)OCTAGONAL WINDOW
 E)GARAGE DOOR IF IT WILL BE REPLACED.
 F)PROVIDE SPECS/SHOP DRAWINGS FOR SPIRAL
 STAIRS.
 15-PROVIDE COMPLETE FRAMING DETAILS FOR
 ROOF SKYLIGHTS. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 16-SEE COMMENTS ON REVIEWED PLAN AND
 PLEASE RETURN REVIEWED SET AFTER
 CORRECTIONS ARE DONE TO THE ORIGINAL
 DRAWINGS AND SPECS TO EXPEDITE THE
 REVIEW PROCESS.
 17-PROVIDE COMPLETE SECTION DETAIL AND
 SPECS FOR NEW SUNDECK.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved