| Plan Review Notes For Permit 02040494 |
| Permit Number |
02040494 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2002-04-23 00:00:00 | ***************PROVISO***************** | | | | | | 1. NEED PRODUCT APPROVALS FOR ROOF MATER | | | IALS | | | | | | 2. 2/12 SLOPE REQUIRES 2 LAYERS UNDERLAY | | | MENT PER FBC 2001 SEC. 1507.3.8 | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 659-8096 EXT. 8394 | | | 3] | | | RE-ENGINEER 2X4 STRUCTURAL ROOF FRAMING | | | TO INCLUDE RIDGE BEAM, 2X RAFTERS, 2X | | | COLLAR TIES, AND 2X PERIMETER BEAM | | | INCLUDE SIZE OF WOOD, NAILING. ROOF | | | DECK TO BE SOLID SHEATHING 5/8 CDX | | | MINIMUM. | | | 4] | | | ZONING REQUIRES A MINIMUM OF 5' SEBACK | | | SIDE AND REAR FOR ALL STRUCTURES. | | | 5] | | | COMPLETE ELECTRICAL INFORMATION IS | | | REQUIRED FOR SEPERATE PERMIT | | | 6] | | | PROVIDE DETAILS FOR FOUNDATION. | | | | | | L. MARTINEZ | | | 659-8096 | | | #8456 |
|