| 2002-09-30 00:00:00 | DENIED BY BUILDING |
| | |
| | 1) STRUCTURE MUST REMAIN A SINGLE FAMILY |
| | RESIDENCE PER CITY OF WPB ZONING |
| | DEPARTMENT. THEREFORE, ITEMS 1 AND 13 ON |
| | FIRST REVIEW ARE NOT REQUIRED. PLEASE |
| | REVISE SHEET 1 FROM MULTIFAMILY TO |
| | SINGLE FAMILY. |
| | |
| | 2) THE ENTIRE STRUCTURE IS REQUIRED TO |
| | BE MADE TO CONFORM TO THE REQUIREMENTS |
| | FOR A NEW STRUCTURE DUE TO THE REPAIRS |
| | AMOUNTING TO MORE THAN 50% OF THE VALUE |
| | OF THE EXISTING BUILDING. SEE 2001 FBC |
| | SECTION 3401.7.2.6. |
| | |
| | 3) PROVIDE ENERGY CALCULATIONS AND |
| | MANUAL J CALCULATIONS AS REQUIRED BY THE |
| | FBC CHAPTER 13. |
| | |
| | 4) INDICATE DESIGN INFORMATION ON PLANS. |
| | 2001 FL. BLD CODE 1606.1.7 THE FOLLOWING |
| | INFORMATION RELATED TO WIND SHALL BE |
| | SHOWN ON THE CONSTRUCTION DRAWINGS, |
| | 1)- BASIC WIND SPEED, MPH |
| | 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| | CATEGORY |
| | 3)- WIND EXPOSURE |
| | 4)- INTERNAL PRESSURE COEFFICIENT, |
| | 5)- COMPONENTS & CLADDING, THE DESIGN |
| | WIND PRESSURES IN TERMS OF PSF. |
| | |
| | 5) SHEETS A2 AND A4 REFERENCE THE WRONG |
| | CODE AND DESIGN CRITERIA. PLEASE REVISE. |
| | THE 2001 FLORIDA BUILDING CODE AND |
| | ASCE 7-98 ARE THE PROPER REFERENCES. |
| | |
| | 6) PLEASE REVISE THE CODE REFERENCES ON |
| | A4 TO FLORIDA BUILDING CODE IN THE |
| | FASTENER SCHEDULE. REVISE #12 UNDER |
| | TYPICAL SECTION NOTES TO REFERENCE |
| | ASCE 7-98. |
| | |
| | 7) REVISE ITEM #9 UNDER TYPICAL SECTION |
| | NOTES ON A4 TO ALL WINDOWS. |
| | |
| | 8) INDICATE ON THE PLANS THAT ADEQUATE |
| | SUBSTRATE IS TO BE PROVIDE FOR THE |
| | ATTACHMENT OF THE STORM PANELS. |
| | |
| | 9) PROVIDE (2) COPIES OF AN INSTALLATION |
| | SCHEDULE AND KEY PLAN FOR THE HURRICANE |
| | PANELS. |
| | |
| | 10) PLEASE REVISE SHEET A3 WHICH SHOWS A |
| | KITCHEN ON THE SECOND FLOOR. |
| | |
| | 11) INDICATE THE UNDER FLOOR INSULATION |
| | AT THE FIRST FLOOR AS REQUIRED BY FBC |
| | CHAPTER 13. |
| | |
| | 12) STUCCO ON LATHE AS INDICATED ON WALL |
| | SECTIONS ON A5 IS REQUIRED TO BE 7/8" |
| | THICK PER FBC 2504.2.1 AND ASTM C 926. |
| | |
| | 13) A CONTINOUS LOAD PATH FROM THE ROOF |
| | TO THE FOUNDATION IS REQUIRED TO |
| | TRANSFER THE LOADS. NO CONNECTORS ARE |
| | SHOWN ON A5 TO CONNECT THE BOTTOM PLATE |
| | AND FLOOR JOISTS TO SILL PLATE AT THE |
| | FIRST FLOOR. NO CONNECTORS ARE INDICATED |
| | FROM TOP PLATES ON FIRST FLOOR TO BOTTOM |
| | PLATE OF SECOND FLOOR. INDICATE THESE |
| | CONNECTORS ON THE PLANS. |
| | |
| | 14) FIREBLOCKING IS REQUIRED BETWEEN THE |
| | FLOOR AND WALL ASSEMBLIES ON THE FIRST |
| | AND SECOND FLOORS PER FBC 2305.1. PLEASE |
| | SHOW THIS ON THE PLANS. INDICATE THE |
| | LOCATION AND MATERIALS USED TO DRAFTSTOP |
| | THE FLOOR/CEILING ASSEMBLY INTO 500 SQFT |
| | AREAS PER FBC 2305.2.2. |
| | |
| | 5) INDICATE THE ATTIC ACCESS ON THE |
| | PLANS THAT COMPLIES WITH 2309.6. |
| | |
| | 16) EMERGENCY ESCAPE AND RESCUE OPENINGS |
| | ARE REQUIRED AT SLEEPING ROOMS PER 2001 |
| | FBC 1005.4. THE 1/2 34SH WINDOWS DO NOT |
| | PROVIDE REQUIRED NET CLEAR OPENING AREA |
| | FOR THE SECOND FLOOR OR THE CLEAR |
| | OPENING HEIGHT. THE ROOMS WHICH HAVE |
| | CLOSETS MUST ALSO COMPLY. |
| | |
| | 17) INTERIOR AND EXTERIOR STAIRS MUST BE |
| | MADE TO COMPLY WITH 2001 FBC. PROVIDE |
| | DETAILS OF STAIRS, HANDRAILS AND GUARD- |
| | RAILS. THE INTERMEDIATE RAILS ON THE |
| | STAIRS MUST REJECT THE PASSAGE OF A 4" |
| | DIAMETER SPHERE THROUGH ANY OPENING. THE |
| | PICKETS INDICATED ON SHEET A2 DO NOT |
| | COMPLY. |
| | |
| | 18) PROVIDE COPIES OF SURVEY INDICATING |
| | DISTANCES TO THE PROPERTY LINES IN ORDER |
| | TO DETERMINE COMPLIANCE WITH TABLE 600 |
| | FOR PERCENT OF WALL AREA ALLOWED AS WALL |
| | OPENINGS. |
| | |
| | 19) PROVIDE ELEVATIONS. INDICATE FLOOR, |
| | CEILING, CRAWL SPACE, ETC. ELEVATIONS. |
| | INDICATE THE MEAN ROOF HEIGHT AND ROOF |
| | PITCH ON THE PLANS. |
| | |
| | 20) INDICATE THE POSITIVE AND NEGATIVE |
| | WINDLOAD PRESSURES FOR ALL EXTERIOR DOOR |
| | AND WINDOW OPENINGS ON THE PLANS. |
| | |
| | 21) PROVIDE (2) CURRENT AND COMPLETE |
| | COPIES OF SBCCI OR METRO-DADE PRODUCT |
| | APPROVALS FOR: |
| | - EXTERIOR WOOD DOOR |
| | - EXTERIOR ALUMINUM DOOR |
| | THE PRODUCT APPROVAL THAT WAS SUBMITTED |
| | IS FOR AN EXTERIOR STEEL DOOR WHICH IS |
| | NOT INDICATED ON THE PLANS. |
| | |
| | 22) THE DOOR SCHEDULE ON A2 INDICATES |
| | HOLLOW CORE WOOD EXTERIOR DOORS. CHAPTER |
| | 13 OF THE FBC DOES NOT ALLOW THIS TYPE |
| | OF DOOR TO BE USED AT THE EXTERIOR. |
| | PLEASE REVISE. |
| | |