| Plan Review Notes For Permit 02040130 |
| Permit Number |
02040130 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2002-04-21 00:00:00 | DENIED | | | REFERENCE: FBC-2001 SEC 424.2 PRIVATE | | | POOLS | | | | | | 1) PLEASE ADJUST NOTES AND DETAILS FOR | | | POOL PLANS FOR REVIEW. | | | A) | | | FBC-2001 SEC 424.2.6.6.2 SHOW COMPLIANCE | | | WITH ANSI/ASME A112.19.8M. PROVIDE MODEL | | | NUMBER AND MANUF INFO FOR VAC LOCK. | | | (GIVE DETAIL OR ADD NOTE)(SUBMITTAL) | | | B) | | | FBC-2001 SEC 424.2.7.1 POOL CIRCULATING | | | PUMPS SHALL BE EQUIPPED ON THE INLET | | | SIDE WITH AN APPROVED TYPE HAIR AND LINT | | | STRAINER WHEN USED WITH A PRESSURE FIL- | | | TER. (DETAIL) | | | C) | | | FBC-2001 SEC 424.2.12.1 PRESSURE TESTS. | | | PER MANUFACTURE RECOMMENDATIONS, NO AIR | | | TEST SHALL BE APPROVED FOR PVC PIPE AND | | | FITTINGS. (ADD TO NOTES) | | | 2) PLEASE SUBMIT AN ISOMETRIC FOR THE | | | POOL EQUIPMENT AND PIPING. INDICATE PIPE | | | SIZES, VALVES, VENTS, BYPASSES AND RE- | | | LATED PUMPS, FILTERS, HEATER EXT. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|