Plan Review Notes
Plan Review Notes For Permit 02040084
Permit Number 02040084
Review Stop B
Sequence Number 5
Notes
Date Text
2003-01-29 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 REVISION SUBMITTED 1-16-03 FOR EXTENDING
 THE GARAGE AND INSTALLING A 2ND FLOOR
 BATHROOM.
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 1) PLEASE NOTE THAT THE PROVISOS DATED
 12-6-02 STILL STAND, AS THEY HAVE NOT
 YET BEEN ADDRESSED.
  
 2) THE ROOF PROFILE AND WEST ELEVATION
 WALL WOULD BE CHANGED BY THE PROPOSED
 PERMIT PLAN REVISION.SUBMIT A REVISED
 WEST ELEVATION TO SHOW THIS.
  
 3) NO NEW DOOR AND WINDOW SCHEDULE HAS
 BEEN SUBMITTED.THE GARAGE AND LAUNDRY
 WINDOWS W, Y AND Z ON SHEET A-2 DO NOT
 CORRELATE WITH THE PERMIT APPROVED
 SCHEDULE.ALSO, THE GUEST BATH WINDOW
 REFERENCE 'V' IS SHOWN ON THE SCHEDULE
 AS A GARAGE DOOR.SUBMIT A CORRECTED
 SCHEDULE
  
 4) THE SIZE OF THE GARAGE DOOR HAS BEEN
 INCREASED.SUBMIT A PRODUCT APPROVAL
 AND REVISE THE DOOR SCHEDULE TO SPECIFY
 THE NEW DOOR.
  
 5) THE EXTERIOR DOOR AT THE REAR OF THE
 GARAGE IS SHOWN AS 'X', WHICH THE
 SCHEDULE CALLS UP AS 'EXISTING'.WHICH
 EXISTING DOOR IS TO BE USED?IF A NEW
 DOOR IS REQUIRED, SUBMIT A PRODUCT
 APPROVAL.
  
 6) FBC 2405.2THE WINDOW ADJACENT THE
 PROPOSED 2ND FLOOR BATH TUB IS IN A
 'HAZARDOUS LOCATION' AND IS REQUIRED
 TO BE SAFETY GLASS SATISFYING THE
 REQUIREMENTS OF THE CONSUMER PRODUCT
 SAFETY COMMISSION 16, CODE OF FEDERAL
 REGULATIONS, PART 1201 (CPSC 16-CFR,
 PART 1201).SUBMIT DETAILS TO
 DEMONSTRATE COMPLIANCE.
  
 7) THERE ARE ARCHITECT'S AND ENGINEER'S
 HAND-WRITTEN REVISIONS, ON THE PERMIT
 APPROVED ARCHITECTURAL AND STRUCTURAL
 PLANS, THAT HAVE NOT BEEN ADDED TO THE
 REVISED PLAN SET. THE OMISSIONS INCLUDE,
 BUT ARE NOT LIMITED TO, THE HAND-WRITTEN
 REVISION TO NOTE 9 OF THE PERMIT
 APPROVED COPY OF SHEET A-2, THE BEAM
 SCHEDULE ON SHEET S-1, AND THE
 'CONSTRUCTION NOTES' AND HAND-DRAWN
 ATTIC ACCESS PANEL IN THE CLOSET ON THE
 PERMIT APPROVED COPY OF SHEET A-3. CHECK
 AGAINST THE PERMIT APPROVED PLANS AND
 AMEND THE REVISION PLAN SET TO SHOW THE
 REQUIRED INFORMATION.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS