| Date |
Text |
| 2002-04-25 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT # 02031587 |
| | 265 GRANADA ROAD |
| | CONT: BRANCH CONST |
| | TEL: 833-6206 |
| | |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | 1) SHEET 2 OF 4 STRUCTURAL NOTES : |
| | SBC 1205 @ 140 MPH WIND NOT THE SOUTH |
| | FL CODE, 2001 FL BLD CODE |
| | 2) SAME CODE DATA INDICATES THE 1997 |
| | STANDARD BUILDING CODE WRONG, 2001 |
| | FL BLD CODE |
| | 3) THE PLANS INDICATE A 32"WX 20"H |
| | ACCESS FOR THE EXISTING CRAWL SPACE THAT |
| | WILL BE COVERED BY THE NEW ADDITION, |
| | HOW WILL ACCESS BE GAINED? |
| | 4) SHEET 2 ALSO DETAILS A CONCRETE |
| | STAIR,FL BLD CODE 1012.1.5 REQUIRES A |
| | MINIMUM OF A 3'-0" LANDING BEFORE THE |
| | STAIRS BEGIN, THE LANDING MAY BE 7" |
| | LOWER THAN THE INSIDE FLOOR LEVEL. |
| | 5)- THE SAME DETAIL, HANDRAILS FL BLD |
| | CODE1007.5.1 HANDRAILS ARE REQUIRED WHEN |
| | THERE IS 4 OR MORE RISERS ABOVE FLOOR OR |
| | FINISHED GRADE |
| | 6) FL BLD CODE 1007.5.2 STAIRWAYS SHALL |
| | HAVE HANDRAILS ON BOTH SIDES, EXCEPTION |
| | IS WITHIN DWELLING UNIT. |
| | 7) FL BLD CODE 1606.1.5: COMPONENTS & |
| | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| | OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| | TESTING REPORT, SBCCI OR DADE COUNTY |
| | REPORT ARE ACCEPTED. |
| | WOOD DOUBLE HUNG WINDOW |
| | WOOD FRENCH DOORS |
| | TRANSOM ABOVE |
| | MULLIONS |
| | 8) SITE SPECIFIC ENGINEERING (PRODUCT |
| | APPROVAL) REQUIRES THE WET SIGNATURE, |
| | DATE AND EMBOSSED SEAL OF THE ENGINEER |
| | CERTIFYING THE PRODUCT AND OF THE DESIGN |
| | PROFESSIONAL OF RECORD. IF PRODUCT |
| | TESTING ISN'T AVAILABLE. SEE ADDITIONAL |
| | INFORMATION. |
| | 9) FLBLD CODE 1511.6.4.3 EMERGENCY OVER- |
| | FLOW FOR ROOF, SCUPPER ARE TO BE PLACED |
| | LEVEL WITH ROOF, OVERFLOW SHALL NOT BE |
| | PLACED LESS THAN 2" ABOVE ROOF LEVEL & |
| | NOT MORE THAN 4". |
| | 10-PROVIDE ENERGY CALCULATIONS AND |
| | EQUIPMENT SIZING CALCULATIONS (MANUAL J) |
| | AS REQUIRED BY THE 1997 FLORIDA ENERGY |
| | EFFICIENCY CODE FOR BUILDING |
| | CONSTRUCTION. |
| | 11-IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY, PLANS STAMPED BY THEM AND |
| | COPY OF RECEIPT SUBMITTED TO CITY OF |
| | WEST PALM BEACH BUILDING DEPARTMENT, |
| | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| | ANY QUESTIONS PLEASE CALL, |
| | JIM WITMER |
| | BUILDING PLAN REVIEW |
| | DEPARTMENT OF CONSTRUCTION SERVICES |
| | CITY OF WEST PALM BEACH |
| | (561) 659-8096 EXT. 8412 |