| Plan Review Notes For Permit 02031545 |
| Permit Number |
02031545 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2002-06-27 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | | | | 1) FROM PREVIOUS REVIEW: SHT P-2 WATER | | | HAMMER ARRESTORS SHALL BE REQUIRED FOR | | | QUICK CLOSING VALVES AND LOCTED NEAR THE | | | FIXTURE IN AN "EFFECTIVE RANGE" NOT AT | | | TOP OF DROP AS SHOWN. SEC 604.9 | | | 2) SHT P-2 PLUMBING NOTES #13 AIR | | | CHAMBERS NOT APPROVED. DELETE REFERENCE | | | 3) FROM PREVIOUS REVIEW: TOILET ROOMS | | | ARE NOT WIDE ENOUGH. MINIMUM WITH IS | | | 5'3". SEE SHT A-4 DETAILS ALSO | | | 4) SHT A-2 SNACK ROOM SINK TO COMPLY | | | WITH 11-4.24.1 THRU 11-4.24.7 PLEASE | | | PROVIDE DETAILS. FROM PREVIOUS REVIEW. | | | ------NEW COMMENTS------ | | | 5) PER TABLE 403.1, A DRINKING FOUNTAIN | | | AND A SERVICE SINK IS REQUIRED. PLEASE | | | SHOW FIXTURES ON RESUBMITTED PLANS. | | | 6) PLEASE REMOVE ALL VOIDED/SUPERSEDED | | | SHEETS AND PLACE NEW SHEETS IN PLAN FOR | | | REVIEW. RESUBMIT ONE SET OF OLD SHEETS | | | FOR COMPARISON SEPARATE FROM NEW COMPLE- | | | TE SET. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|