| 2002-04-12 00:00:00 | | | | 1.AS PER 2001 FMC, OUTSIDE AIR EXHAUST | | | AND INTAKE OPENINGS SHALL BE LOCATED | | | A MINIMUM OF 10 FT FROM LOT LINES OR | | | BUILDINGS ON THE SAME LOT. FBC 401.5 | | | | | | 2.FMC 401.5.2, EXHAUST AIR SHALL NOT | | | BE DIRECTED ONTO WALKWAYS. | | | | | | 3.SEE FIRE DEPARTMENTS COMMENTS AS TO | | | STORAGE WITHIN THE BUILDING. | | | | | | 4.CLARIFY LOCATION AND SEPARATION OF | | | THE OUTSIDE AIR IN REFERENCE TO THE | | | EHXAUST OF CONDENSERS. | | | | | | PROVISO: | | | | | | AS PER 2001 FBC 1503.4.4, CONDENSATE | | | SHALL DISCHARGE A MINIMUM OF 12 INCHES | | | FROM THE BUILDING STRUCTURE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|