| Plan Review Notes For Permit 02031481 |
| Permit Number |
02031481 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2002-05-17 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) FROM PREVIOUS REVIEW: SHT A-1 DRINK- | | | ING FOUNTAIN, SECTION 4.1.3(10) PLEASE | | | SHOW COMPLIANCE FOR THOSE WHO HAVE DIFF | | | ICULTY BENDING OR STOOPING. | | | 2) FROM PREVIOUS REVIEW: SHT M-1 PLUMB- | | | ING PLAN AND SANT RISER DIAGRAM, FLOOR | | | DRAIN NOT APPROVED FOR INDIRECT WASTE | | | FOR WATER HEATER T/P RELIEF DISCHARGE. | | | FLOOR SINK REQUIRED FOR ALL INDIRECT | | | WASTE, AND A TRAP PRIMER IS REQUIRED TO | | | PROTECT SEAL OF TRAP. SEC 802.3 | | | 3) SERVICE SINK IS REQUIRED PER TABLE | | | 403.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|