| Plan Review Notes For Permit 02031079 |
| Permit Number |
02031079 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2002-06-25 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | | | | 1) FROM PREVIOUS REVIEW: DIMENTIONS FOR | | | TOILET ROOMS NOT SHOWN. MINIMUM TOILET | | | SIZE FOR TOILET ROOMS WITH DOOR IN FRONT | | | IS 7'5" X 5'3". 5' TURNING RADIUS SHALL | | | NOT INCLUDE SPACE OCCUPIED BY THE WATER | | | CLOSET. | | | 2) FROM PREVIOUS REVIEW: WATER CLOSETS | | | SHALL BE LOCATED 1'6" OFF THE WALL TO | | | THE CENTER OF FIXTURE. | | | 3) ALL GAS INFORMATION REQUESTED SHALL | | | BE SUBMITTED AT TIME OF GAS PERMIT | | | APPLICATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|