| Plan Review Notes For Permit 02022300 |
| Permit Number |
02022300 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2002-04-01 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FHA AMEND-98 DESIGN | | | MANUAL | | | | | | 1) SHT A-16 SANITARY RISER DIAGRAM UNITS | | | "A" & "C" - BATH #3 FROM "C" UNIT SHALL | | | NOT DRAIN PAST LAUNDRY TRAY ON FIRST | | | FLOOR. BATH #3 SHALL BE TAKEN OFF BELOW | | | LAUNDRY TRAY. | | | 2) SHT A-16 SANITARY RISER DIAGRAM UNITS | | | "A" & "C" - MASTER BATH FROM "C" UNIT | | | SHALL NOT DRAIN INTO 2" DRAIN FROM SHOW- | | | ER. RISER FOR MASTER BATH SHALL BE TAKEN | | | OFF BEFORE MASTER BATH IN "A" UNIT. | | | 3) SHT A-16 SANITARY RISER DIAGRAM UNITS | | | "B" & "D" - LAUNDRY TRAY NOT SHOWN FOR | | | UNIT "D" | | | 4) SHT 1-16 SANITARY RISER DIAGRAM UNITS | | | "B" & "D" - MASTER BATH FROM "D" UNIT | | | SHALL NOT DRAIN INTO 2" DRAIN FROM SHOW- | | | ER. RISER FOR MASTER BATH SHALL BE TAKEN | | | OFF BEFORE MASTER BATH IN "B" UNIT. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|