| Notes |
| Date |
Text |
| 2002-03-08 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT # 02022228 | | | 105 EVERNIA ST | | | CONT: RAY QUALMANN MARINE | | | TEL: (954) 941-0132 | | | FAX: (954) 943-6430 | | | | | | **********PROVISO********* | | | | | | 1)- THE PLAN DO NOT CLEARLY INDICATE | | | COMPLIANCE WITH FLORIDA ACCESSIBILITY | | | CODE, 1997. AT LEAST ONE ACCESSIBLE | | | ROUTE COMPLYING WITH 4.3 SHALL CONNECT | | | ALLACCESSIBLE SPACES & ELEMENTS. | | | 2)- GROUND AND FLOOR SURFACES ALONG THE | | | ACCESSIBLE ROUTE SHALL COMPLY WITH 4.5 | | | ADDAGG 4.5 A STATIC COEFFICIENT OF | | | FRICTION OF 0.6 IS RECOMMENDED FOR | | | ACCESSIBLE ROUTES, AND 0.8 FOR RAMPS. | | | 3)- RAMPS, THE PLANS DO NOT INDICATE | | | THE RAMPS THAT WILL BE REQUIRED TO CROSS | | | THE BULKHEAD, THESE RAMPS MUST COMPLY | | | WITH ALL REQUIREMENTS OF 4.8. ALL LAND- | | | INGS AND HAND RAILS TO HAVE HANDRAILS ON | | | BOTH SIDES. | | | 4)- GANG PLANKS ARE TO CONFORM TO AN | | | ACCESSIBLE ROUTE, SLOPE AS WELL TRANSI- | | | TION PLATES AT THE TOP AND BOTTOM FOR | | | WHEEL CHAIR ACCESS TO FLOATING DOCKS. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 X8412 |
|