1 |
|
| Notes |
| Date |
Text |
| 2002-03-05 00:00:00 | DENIED | | | REFERENCE: SPC-94 | | | | | | 1) PLEASE ROUTE PLANS TO DEPT. OF BUSIN- | | | ESS REGULATION HOTEL & BUSINESS DIVISION | | | FOR PLAN REVIEW BEFORE RESUBMITTING FOR | | | PLAN REVIEW FOR PERMIT. | | | 2) SHT SM.P1 PLUMBING & RISER PLANS, ICE | | | BIN TO BE INDIRECT WASTE TO FLOOR SINK. | | | SPC SEC 804.5/804.5.1. | | | 3) SHT SM.P1 PLUMBING & RISER PLANS, 3 | | | COMPARTMENT SINK TO BE INDIRECT WASTE TO | | | FLOOR SINK. | | | 4) SHT SM.P1 SINK SUMP TO BE LOCATED | | | BELOW SLAB TO TAKE INDIRECT WASTE FROM | | | FLOOR SINK. | | | 5) SHT SM.P1 VENT FROM SUMP SHALL VENT | | | SEPARATELY. SEC 915 | | | 6) SHT SM.P1 DRAINAGE FROM SUMP SHALL | | | NOT DRAIN INTO MOP SINK. AN APPROVED | | | INDIRECT WASTE RECEPTOR SHALL BE USED. | | | (FLOOR SINK). | | | | | | REVEIW BY KEN STEVENS | | | (561)659-8096 EXT 8377 |
|