| Plan Review Notes For Permit 02021544 |
| Permit Number |
02021544 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2002-03-02 00:00:00 | DENIED; | | | SANITARY RISER DIAGRAM; | | | 1.MASTER BATH BIDET NOT VENTED. | | | 2.POWDER BATH UNVENTED (NO VENT ON LAV) | | | 3.SECOND FLOOR BATH 3 W/C UNVENTED. | | | 4.NO MORE THAN 2 W/C ON 3" HORIZONTAL | | | BRANCH 94 SPC TABLE 714.1 NOTE 3. | | | 5.BATH 4 TUB NOT VENTED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT 8369 |
|