Date Text
2002-04-08 00:00:00BUILDING PLAN REVIEW
 PERMIT # 02021544
 141 GREGORY PLACE
 O/B MICHAEL SAINT JOHN
 H 586-0484
 B 874-8610 BEEPER
  
 SBC= 1997 STANDARD BUILDING CODE
 SBC*= AMENDMENTS STANDARD BUILDING CODE
  
 1)- MISSING PRODUCT APPROVALS:
 A) WINDOW MULLION REPORT
 B) GARAGE SIDE DOOR ENTRY
 C) OVERHEAD GARAGE DOOR
 D) GLASS BLOCK ALSO WALL THICKNESS OF
 THE GLASS BLOCK?
 2) FIXED WINDOWS REPORT MISSING THE
 TECH. DRAWINGS AND PRESSURES +/-.
 3)- 2ND FLOOR LIVING ROOM REAR ELEVATION
 INDICATES (3) FIXEDWINDOWS VS. FLOOR
 PLAN, A-2, 2ND FLOOR PLAN INDICATES
 (3)25 SH WINDOWS ?
 4)- SHEET S-2 INDICATES HUGHES CONNECTIO
 NS ON PLAN, THEY ARE NO LONGER IN BUSI-
 NES.
 5)- SHEET S-3 CONN SCHEDULE HETAL-16,
 SCHEDULE INDICATES 1365 LBS UPLIFT,
 IS THIS A TYPE-O? SIMPON @ 160% INDI-
 CATES 1635? CONNECTION #1 ON PLAN INDI-
 CATES 1653 WITH 1 CONNECTION?
 SHEET S-4 INDICATES STUCCO SOFFIT, NO
 SPEC AS TO WIRE LATH OR NAILING FOR
 HORIZONTAL SURFACES? SEE ASTM 1063
 7.10.2.3. EXPANED 3/8" RIB LATH AND
 SHEET LATH SHALL BE ATTACHED TO HORIZON-
 TAL WOOD SUPPORTS.7.10.1.1 FOR 3/8 RIB
 LATH SHALL BE ATTACHED AT EACH RIB (4").
 6)- THE CONTRACTOR SHALL SUBMIT THE
 PLANS TO PALMBEACH COUNTY BUILD. DEPT
 FOR IMPACT FEE ASSESSMENT BEFORE THE
 ISSUANCE OF PERMIT.
 7)- PAY STATE RADON FEES TO CITY.
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)659-8096 X 8412