Plan Review Notes
Plan Review Notes For Permit 02021497
Permit Number 02021497
Review Stop B
Sequence Number 2
Notes
Date Text
2002-11-14 00:00:00SECOND CHECKLIST:
 1-NEED RECORDED NOTICE OF COMMENCEMENT.
 2-PROVIDE ENERGY CACULATIONS AS REQUIRED
 BY FLORIDA ENERGY EFFICIENCY CODE FOR
 BUILDING CONSTRUCTION, 1997 ED.
 3-PROVIDE SOIL TEST REPORT. SECTION
 1804.2.7.2 CITY AMENDMENTS TO SBC 1997
 4-PROVIDE COMPLETE SECTION/DETAILS AND
 SPECS THRU CONCRETE BLOCK COLUMNS AT
 REAR PORCH. SPECIFY ATTACHMENT OF
 VERTICAL REINFORCEMENT TO LINTELS.
 **NOTE: PROVIDE COMPLETE STRUCTURAL
 SPECIFICATIONS FOR LINTELS TO BE USED.
 SEC. 104.2.1.2 CITY AMENDMENTS TO SBC.
 5-SPECIFY SPECIFIC LOCATION OF STORAGE
 SHED FOR ZONING REVIEW.
 6-NEED COMPLETE INFORMATION (2 COPIES)
 FOR STORM PANELS AND:
 A)KEY PLAN AND COMPLETE INSTALLATION
 SCHEDULE. SEE CITY SAMPLE.
 B)CLEARLY INDICATE ON DRAWINGS SPECIFIC
 MOUNTING CONDITIONS AND ANCHOR TYPE &
 SPACING TO BE USED ACCORDING TO THE
 DESIGN PRESSURES, PANEL SPAN, EDGE
 DISTANCE, MEAN ROOF HEIGHT, CONNECTION
 TYPE AND STRUCTURE TO BE ATTACHED TO.
 7-CLARIFY FINISH ROOF MATERIAL. DRAWINGS
 CALL FOR CEMENT TILE, BUT PRODUCT
 APPROVAL SUBMITTED IS FOR SHINGLES.
 8-DECLARED CONTRUCTION VALUE IS TOO LOW.
 OWES $642.96 FOR UPDATED VALUE AND
 RADON FEES.
  
 NOTE: ALL THESE COMMENTS WERE WRITTEN ON
 FIRST REVIEW BUT THEY WERE NOT
 ADDRESSED. ADDITIONAL FEES WILL
 BE CHARGED FOR RE-SUBMITTALS.