| 2002-05-30 00:00:00 | SECOND CHECKLIST: |
| | 1-AFTER CORRECTING ORIGINAL DRAWINGS, |
| | PLEASE PAY IMPACT FEES TO PALM BEACH |
| | COUNTY. BRING BACK STAMPED DRAWINGS |
| | AND COPY OF PAID RECEIPT. |
| | 2-NEED RECORDED NOTICE OF COMMENCEMENT. |
| | 3-CLARIFY DISCREPANCY WITH THE FINISH |
| | FLOOR ELEVATION. ARCHITECT'S SITE PLAN |
| | NOTES SAYS 10.5" ABOVE SEA LEVEL. |
| | SURVEY SAYS 7.5', BUT THE LIVING ROOM |
| | WILL BE AT 7' ACCORDING TO ARCHITECT'S |
| | PLANS. (NEED 7.5'MIN. FIN. FL. ELEV. |
| | AT FLOOD ZONE A5). |
| | ON THE OTHER HAND NEED TO CONSIDER |
| | SOUTH NEIGHBOR FOR DRAINAGE SINCE THE |
| | HOUSE HAS 6.5' FIN. FL. ELEV. |
| | 4-ARCHITECT CHANGED PLANS TO FBC 2001. |
| | SEE COMMENTS ON PLANS & REVISE/UPDATE |
| | THEM AS REQUIRED. NOTE: COMMENTS WERE |
| | NOT REVISED FROM PREVIOUS CHECKLIST. |
| | **PLEASE, PUT TOGETHER TWO NEW SETS AND |
| | RETURN ALL THE REVIEWED DRAWINGS TO |
| | EXPEDITE REVIEW PROCESS. |
| | 5-OWES $662.35 FOR UPDATED VALUATION AND |
| | RADON FEES.PLEASE PAY ATTACHED RECEIPT |
| | 6-PROVIDE ATTIC ACCESS AT MASTER BATHRM |
| | WING. SEC. 2309.6 FBC 2001 |
| | 7-CLEARLY SPECIFY ON PLANS AREAS TO HAVE |
| | SAFETY GLASS. IT'S NOT CLEAR IF ALL |
| | GLASS AREAS WILL BE MISSILE IMPACT |
| | GLAZING OR NOT. SEE SECTION 2405.1 AND |
| | SEC 2405.2 FBC 2001. |
| | 8-PROVIDE PRODUCT APPROVAL FOR: |
| | A)ENTRY DOOR. SEE SIZE, SHAPE AND DESIGN |
| | PRESSURES SHOWN ON PLANS. |
| | B)GARAGE SWING DOOR AS SHOWN ON PLANS. |
| | C)FRENCH DOORS AS SHOWN ON PLANS. |
| | D)CASEMENT WINDOWS (MISSING DRAWINGS). |
| | E)WINDOW MULLIONS (FOR IMPACT ASSEMBLIES |
| | IF USING IMPACT WINDOWS) |
| | F)FIXED WINDOWS AS SHOWN ON PLANS. |
| | G)ARCHED WINDOWS AS SHOWN ON PLANS. |
| | H)FIREPLACE UL LISTING & SPECIFICATIONS. |
| | I)EXTERIOR DOOR AT 3RD FLOOR BALCONY. |
| | SEE SIZE AND SHAPE ON DRAWINGS. |
| | 9-REVISE A/C AREA ON ENERGY CALCULATIONS |
| | TO MATCH A/C AREA ON ARCHITECT'S PLANS |
| | NOTE: OWNERAGENT TO SIGN AND DATE |
| | BOTTOM OF FORM. |
| | 10-PROVIDE COMPLETE INFORMATION FOR |
| | STORM SHUTTERS: KEY PLAN AND COMPLETE |
| | INSTALLATION SCHEDULE. |
| | 11-SPECIFY DRAINAGE & EMERGENCY SCUPPERS |
| | @ 3RD FL BALCONY. SEC. 1503.4 THRU |
| | 1503.4.4 FBC 2001. |
| | 12-SPECIFY ON PLANS HOW SOIL EROSION IS |
| | TO BE PREVENTED FROM WATER IMPACT FROM |
| | ROOF VALLEYS, SCUPPERS. ETC. AS REQ'D |
| | BY SECTION 1804.1.6 FBC 2001. |
| | 13-AFTER ALL CORRECTIONS ARE DONE TO ALL |
| | ORIGINAL DRAWINGS, PLEASE TAKE THEM TO |
| | THE HISTORICAL DISTRICT PLAN REVIEWER |
| | FOR APPROVAL PRIOR TO SUBMITTING THEM |
| | TO THE BUILDING DEPARTMENT. |