2002-03-29 00:00:00CHECKLIST:
 1-NEED RECORDED NOTICE OF COMMENCEMENT.
 2-PAY IMPACT FEES TO PALM BEACH COUNTY.
 BRING STAMPED DWGS AND PAID RECEIPT.
 3-SPECIFY RISER HEIGHT AT ENTRY STEPS.
 SEE SEC. 1007.3 SBC 1997.
 4-SPECIFY ON PLANS AREAS TO HAVE SAFETY
 GLASS. SEC. 2405.2 SBC/97. SEE PLANS.
 5-PROVIDE ATTIC ACCESS AT ENTRY ROOF.
 SEC. 2309.6 SBC 1997.
 6-TWO STORY WALL SECTION. PROVIDE SPECS
 FOR FIRE CUT AT FLOOR TRUSSES. SEE
 SEC. 2305.4 SBC 1997.
 7-FLAT ROOF TO HAVE 1/4"/FT MIN. SLOPE.
 SEC. 1503.1.2.3 SBC 1997.
 8-PROVIDE SCUPPERS AT FLAT ROOF. SEE
 SEC. 1517.6.4.3 SBC 1997.
 9-SPECIFY DRAFSTOPPING MATERIAL AND
 LOCATION AT SECOND FLOOR FRAMING PLAN.
 SEC. 2305.2.2 SBC 1997.
 10-PROVIDE COMPLETE SECTION/DETAIL THRU
 CHIMNEY. SPECIFY ALL FASTENERS AND
 TOP PLATE HEIGHT. SECTION 104.2.2 OF
 CITY AMENDMENTS TO SBC 1997.
 11-PROVIDE COMPLETE FRAMING DETAILS AND
 SPECS FOR CANVAS CANOPY. SECTION
 104.2.2 CITY AMENDMENTS TO SBC 1997.
 12-SPECIFY CEILING INSTALLATION AT ENTRY
 PORCH INCLUDING FASTENERS TO BE USED.
 SEE ASTM C1063.
 SEC. 2504.2 SBC 1997.
 13-PROVIDE SMOKE DETECTOR @ 1ST FLOOR BY
 THE STAIRWAY. SEC. 905.2.2 SBC 1997.
 14-PROVIDE COMPLETE WALL SECTION AT 2ND
 FLOOR WALL SUPPORTED ON TRUSS GIRDER @
 WEST WALL OF BEDROOM #3 AND @ SOUTH
 WALL OF BEDROOM #2.SPECIFY ALL
 FASTENERS TOP AND BOTTOM.
 SEC. 104.2.2 CITY AMENDMENTS TO SBC/97
 15-PROVIDE COMPLETE SECTION/DETAIL AND
 SPECS AT BALCONY GUARDRAI AND INTERIOR
 GUARDRAIL AND RAILINGS THAT COMPLY
 WITH SEC. 1608.2 SBC 1997.
 16-PROVIDE SBCCI OR DADE COUNTY (BROWARD
 COUNTY ARE NOT ACCEPTED) PRODUCT
 APPROVAL FOR:
 A)OUTSWING FRENCH DOOR WITH SIDELITES.
 B)INSWING FRENCH DOORS. SEE PLANS.
 C)UL LISTING AND SPECS.
 D)INSWING ENTRY DOOR. (SEE MASTER BEDRM)
 E)GARAGE DOOR THAT MEETS THE DESIGN
 PRESSURES CALCULATED BY THE ARCHITECT.
 F)IMPACT WINDOW MULLIONS.
 G)ARCHED WINDOWS. SEE PLANS.
 H)FIXED WINDOWS. SEE PLANS.
 17-DESIGN CERTIFICATION FOR BUILDING
 CODE COMPLIANCE FORM IS INCORRECT.
 A)REVISE MEAN ROOF HEIGHT, VELOCITY
 PRESSURE.
 B)ARCHITET TO SIGN, SEAL AND DATE FORM
 AS REQUIRED BY CHAPTER 481 FL. STATUTE
 18-PROVIDE COMPLETE FRAMING DETAILS AND
 SPECS FOR CANOPY AT GARAGE SWING DOOR.
 SEC. 104.2.2 CITY AMENDMENTS TO SBC/97
 19-PROVIDE COMPLETE SPECS FOR PARAPET
 WALL. HOW IS IT ATTACHED TO CONCRETE
 TIE BEAM. STEEL BARS?
 SEC. 104.2.2 CITY AMENDMENTS TO SBC/97
 20-TRUSS DRAWINGS:
 A)PROVIDE SIGNED, SEALED AND DATED
 ENGINEERED DRAWINGS.
 B)TRUSS ENGINEER TO SIGN, SEAL AND DATE
 TRUSS LAYOUT ALSO. CH. 471 FL. STATUTE
 C)ARCHITECT TO REVIEW ALL TRUSS DRAWINGS
 PRIOR TO SUBMITTAL. USE REVIEW STAMP.
 21-SEE PLANS FOR ADDITIONAL COMMENTS.
 PLEASE RETURN REVIEWED SET AFTER
 CORRECTIONS ARE DONE TO THE ORIGINAL
 DRAWINGS IN ORDER TO EXPEDITE THE
 REVIEW PROCESS.
 22-OWES $379.35 FOR UPDATED VALUE AND
 RADON FEES.