| Notes |
| Date |
Text |
| 2002-02-26 00:00:00 | DENIED | | | REFERENCE: SPC-94 | | | | | | 1) SANITARY RISER DIAGRAM DOES NOT MEET | | | CODE OR REFLECT FLOOR PLAN. | | | 2) SHOWER IN 1ST FLOOR BATHROOM NOT | | | VENTED. | | | 3) WASTE ARMS FOR KITCHEN AND LAV ARE | | | LOOKING DOWN NOT OUT TO FIXTURES. | | | 4) SHOW WHERE THE STACK FOR 2ND FLOOR | | | TIES INTO THE BLDG DRAIN. | | | 5) MASTER BATH - BIDET NOT VENTED | | | 6) LAV ARMS LOOKING DOWN NOT OUT TO FIX- | | | TURES. | | | 7) 2ND BATH ON 2ND FLOOR IS BEING TAKEN | | | OFF ON THE RISE WHICH CAN NOT WORK. FIX- | | | TURES WILL BE ABOVE THE FLOOR. | | | 8) PLEASE SUBMIT A SANITARY RISER DIA- | | | GRAM THAT REFLECTS THE FLOOR PLAN AND | | | MEETS CODE REQUIREMENTS. 2 COPIES REQ- | | | UIRED. SPC SEC 104.2.1 & 104.3.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|