| Plan Review Notes For Permit 02020594 |
| Permit Number |
02020594 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2002-03-04 00:00:00 | DENIED | | | REFERENCE: FBC-2001 - FHA-AMEND-98 | | | DESIGN MANUAL | | | | | | 1) FROM PREVIOUS REVIEW - SHT T1.01 | | | COVER SHEET CALLS FOR IRRIGATION SHEETS | | | IR-1 & IR-2, NONE FOUND. PLEASE SUBMIT | | | IRRIGATION SHEETS. | | | 2) FROM PREVIOUS REVIEW - #7 WATER RISER | | | DIAGRAM TYPICAL OF ALL UNITS. WATER HAM- | | | MER ARRESTORS REQUIRED FOR ALL REFRIG. | | | ICE MAKERS. PLEASE SHOW ON RISER DIAG. | | | 3) FROM PREVIOUS REVIEW - #9 SHT P-6, | | | SANT. RISER DIAG. W/MACHINE STACK SHOWS | | | 2" ON HORIZONTAL DRAIN LINE BUT 3" ON | | | VERTICAL STACK PLEASE SIZE DRAIN FOR 3" | | | ALSO. UNIT "B" UNCHANGED | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|