| Date |
Text |
| 2002-02-26 00:00:00 | DENIED |
| | REFERENCE: SPC-94-FACBC-97 |
| | |
| | 1) PLANS SHALL BE ROUTED TO THE PALM |
| | BEACH COUNTY HEALTH UNIT, DIVISION OF |
| | ENVIRONMENTAL HEALTH. 901 EVERNIA STREET |
| | WPB FLA 33401. THIS SHALL BE DONE BEFORE |
| | RESUBMITTING FOR PLAN REVIEW. |
| | 2) PLEASE SUBMIT CALCULATIONS FOR MINI- |
| | MUM FACILITIES. USE SPC TABLE 407 AND |
| | SEC 407.1.3 |
| | 3) SHTS P-1/P-2 GREASE REISE DIA. DOES |
| | NOT REFLECT FLOOR PLAN. FLOOR PLAN SHOWS |
| | THREE FLOOR DRAINS TAKEN OFF FROM BLDG |
| | DRAIN. RISER DIAGRAM SHOWS ONE TAKEN OFF |
| | FROM BLDG DRAIN, AND ONE TAKEN OFF FROM |
| | BRANCH LINE AFTER 3 COMPARTMENT SINK. |
| | 4) SHTS P-1/P-2 FLOOR SINK REQUIRED FOR |
| | INDIRECT WASTE FROM ICE MAKER. FLOOR |
| | DRAIN NOT APPROVED. SPC SEC 804.5 |
| | 5) SHTS P-1/P-2 JANITOR MOP SINK TO BE |
| | ON GREASE WASTE SYSTEM NOT SANITARY. |
| | 6) SHTS P-1/P-2 ANY SINKS IN FOOD PREP |
| | AREA SHALL BE INDIRECT WASTE TO FLOOR |
| | SINK. SPC SEC 804.1 |
| | 7) SHTS P-1/P-2 SANITARY RISER DIAGRAM |
| | DOES NOT REFLECT FLOOR PLAN. |
| | A) SINK BEHIND HDCP LAV IN WOMENS REST |
| | ROOM ON RISER DIAGRAM NOT SHOWN ON FLOOR |
| | PLAN. |
| | B) DRINKING FOUNTAINS BY MENS AND WOMEN |
| | REST ROOMS ON FLOOR PLAN NOT SHOWN ON |
| | RISER DIAG. |
| | C) ARTS & CRAFTS TAKEN OFF BEFORE MENS |
| | ROOM ON FLOOR PLAN BUT NOT ON RISER DIA. |
| | D) CLEAN OUT AT CHANGE OF DIRECTION TO |
| | MENS ROOM MISSING ON RISER DIA. |
| | E) OFFICE BATH ROOM TAKEN OFF AFTER |
| | DRAIN LINE TURNS TO MENS ROOM NOT RE- |
| | FLECTED ON RISER DIA. |
| | F) FLOOR DRAIN BETWEEN URNAL AND W/C IN |
| | MENS ROOM SHOWN ON FLOOR PLAN NOT SHOWN |
| | ON RISER DIAGRAM. |
| | 8) SHT ME-1 PLEASE SUBMIT STORM RISER |
| | DIAGRAM. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 659-8096 EXT 8377 |