| Date |
Text |
| 2002-02-28 00:00:00 | CHECKLIST: |
| | 1-PROVIDE CLEAR DRAWINGS AND SPECS. |
| | SHOWING FULL SCOPE OF WORK. CLEARLY |
| | INDICATE ALL EXTERIOR DOORS & WINDOWS |
| | THAT ARE REPLACED OR NEW. SPECIFY SIZE |
| | & TYPE OF WINDOWS TO CHECK FOR EGRESS |
| | REQUIREMENTS AND STORM SHUTTER POLICY. |
| | 2-ACCORDING TO THE PLANS PRESENTED, IT |
| | LOOKS LIKE A BEARING WALL IS GOING TO |
| | BE DEMOLISHED AND NEW BEAM WILL BE |
| | INSTALLED. PROVIDE COMPLETE STRUCTURAL |
| | DESIGN INFORMATION BASED ON SSTD 10-97 |
| | OR PROFESSIONAL ENGINEER TO PROVIDE |
| | THE STRUCTURAL DESIGN. |
| | -PROVIDE COMPLETE STRUCTURAL DETAILS |
| | AND SPECS SHOWING BEAM SIZE, CONNECTOR |
| | AT BOTH ENDS, TOP & BOTTOM CONNECTORS. |
| | -SPECIFY COLUMNS AT THE ENDS OF BEAM & |
| | HOW IS THE LOAD TRANSFERRED TO THE |
| | FOUNDATION. SPECIFY SIZE OF FOOTING. |
| | SEC. 104.2 CITY AMENDMENTS TO SBC 1997 |
| | 3-PROVIDE COMPLETE FRAMING DETAILS FOR |
| | NEW EXTERIOR DOORS AND WINDOWS. |
| | SPECIFY ALL FASTENERS. SEE SSTD 10-97 |
| | 4-ALL INFORMATION, DRAWINGS, SPECS SHALL |
| | BEAR THE NAME AND SIGNATURE OF THE |
| | PERSON RESPONSIBLE FOR THE DESIGN. |
| | SEC. 104.2.1 CITY AMENDMENTS TO SBC/97 |
| | 5-SEE COMMENTS BY THE OTHER TRADES. |
| | 6-VALUE DECLARED FOR THIS PROJECT IS TOO |
| | LOW. PROVIDE REALISTIC MARKET VALUE |
| | USING MATERIALS AND LABOR. (INCLUDE |
| | LABOR EVEN IF DONE BY THE OWNER). |