| Notes |
| Date |
Text |
| 2002-02-12 00:00:00 | DENIED | | | | | | 1) PLEASE INDICATE WHICH CODE THIS IS | | | DESIGNED FOR. | | | 2) SHT A-1 PLEASE PROVIDE SQUARE FOOTAGE | | | FOR ALL TENANT SPACES AND FOR STORAGE | | | AREA. | | | 3) SHT A-1 IS EXISTING TOILET ROOM AT | | | NORTH WEST CORNER OF STORAGE AREA HDCP | | | ACCESSIBLE, AND CAN IT BE ACCESSED FROM | | | STORAGE AREA? | | | 4) SHT A-1 PLEASE GIVE OCCUPANCY OF EACH | | | TENANT SPACE. | | | 5) SHT A-1 TOILET ROOM DETAIL, PLEASE | | | INDICATE THAT W/C SHALL BE 1'6" TO | | | CENTER AND LAV SHALL BE 1'3" TO CENTER. | | | 6) SHT ME-2 SANT RISER ISOMETRIC SHOWS | | | 2" AT TIE IN TO EXISTING. MINIMUM 4" IS | | | REQUIRED FOR STANDARD CODE AND 3" FOR | | | FLA. BUILDING CODE 2001. | | | 7) SHT ME-2 PLEASE PROVIDE A WATER RISER | | | DIAGRAM. SHOW LOCATION OF WATER HAMMER | | | ARRESTORS NEAR FIXTURES NOT AT TOP OF | | | DROPS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|