2002-02-04 00:00:00*************BUILDING FAILED**********
  
 1.PERMITS FOR SWIMMING POOLS APPLIED
 FOR AFTER JAN. 1, 2002 MUST COMPLY WITH
 FBC 2001 SEC. 424. PRIVATE SWIMMING
 POOLS START WITH424.2.
  
 2.SHOW THAT THE DESIGN, TOGETHER WITH
 ANY NECESSARY NOTATIONS, ENSURE THAT
 THE CONSTRUCTION AND WORKMANSHIP WILL
 COMPLY WITH ANSI/NSPI-5. SEE FBC 424.2.6
  
 3.PER CHA. 13 SEC. 612.1ABC.2.3.2 OF THE
 FLORIDA BUILDING CODE A POOL COVER IS
 REQUIRED. INDICATE COMPLIANCE ON PLAN.
  
 4. SHOW THE LOCATION/ DETAIL OF THE PUMP
 AND EQUIPMENT FOUNDATION (SEE FBC
 424.2.22)
  
 5. CLEARLY SHOW THE METHOD OF SWIMMING
 POOL ENCLOSURE-BARRIER AS PROVIDED FOR
 IN FBC 424.2.17 ON PLANS.
  
 SEE PLUMBING PROVISO ATTACHED TO PLANS
 FOR FURTHER REQUIREMENTS.
  
  