2002-02-11 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 THE PLANS MAKE REFERENCE TO STANDARD
 BUILDING CODE 1997 AND HAVE THEREFOR
 BEEN REVIEWED FOR COMPLIANCE WITH THAT
 CODE.
  
 SBC = STANDARD BUILDING CODE 1997
 SBC*= STANDARD BUILD'G CODE (CITY AMEND)
 FL ACC CODE = FLORIDA ACCESSIBILITY CODE
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) SBC 1004.1.2THE REAR DOOR (NO. 12)
 MAY BE REQUIRED AS AN EXIT IF THE TRAVEL
 DISTANCE WOULD OTHERWISE EXCEED 75' (SEE
 COMMENT 5, BELOW).IF SO, THE EXIT MUST
 NOT BE OBSTRUCTED BY FURNITURE, AS IS
 IMPLIED BY THE ROOM 112 LAYOUT.ALSO,
 EXIT SIGNS WOULD BE REQUIRED IN ORDER TO
 SUIT THE PROVISON OF AN ADDITIONAL EXIT.
  
 3) SBC 1012.1.7MEANS OF EGRESS DOORS.
 WITH REFERENCE TO COMMENT (2) ABOVE,
 DOORS 02, 03 AND 06 SHALL BE OPENABLE
 WITHOUT THE USE OF A KEY IN ORDER TO
 PROVIDE ACCESS TO THE REAR EXIT DOOR
 (NO. 12).
  
 4) SBC* 104.2 NEW SLAB, SHEETS A-1 & P-1
 SUBMIT DETAILS TO DESCRIBE THE SUBGRADE
 MAKE-UP UNDER THE AREA OF NEW FLOOR SLAB
 AT THE REAR OF THE PREMISES.
  
 5) FL ACC CODE 4.1.6(1)(A) AND 4.13(1).
 SHEET A-1, FLOOR PLAN.WHAT IS
 REPRESENTED BY THE TWO CONCENTRIC LINES
 WHICH ARE APPROXIMATELY MIDWAY BETWEEN
 R4'-11" AND R10'-4"?A MINIMUM CLEAR
 WIDTH OF 36" IS REQUIRED BETWEEN THE
 CHAIRS/TABLES, SHOWN EACH SIDE OF THE
 RECEPTION DESK, AND THE NEAREST
 OBSTRUCTION.ANNOTATE PLANS TO CLARIFY.
  
 6) FL ACC CODE 4.15.2DRINKING FOUNTAIN
 SPOUT HEIGHT.THE DIMENSIONS ON
 SHEET A-3 STATE THAT THE SPOUT HEIGHT IS
 36" MIN. ABOVE FLOOR, THIS SHOULD READ
 36" MAX. AS SHOWN ON FIGURE 27.
  
 7) FL ACC CODE 4.19.3CLEAR FLOOR SPACE
 AT SINK.THE DIMENSIONS ON SHEET A-3
 SHOW THE FRONT EDGE OF THE SINK AND THE
 EXTENT OF THE REQUIRED FLOOR SPACE AS
 BEING 19" MAX. AND 48" MIN. RESPECTIVELY
 MEASURED FROM THE WALL.THE DIMENSIONS
 SHOULD BE MEASURED FROM THE KNEE
 CLEARANCE LIMIT AS SHOWN ON FIGURE 32.
 ALSO, THE TOE CLEARANCE AND KNEE
 CLEARANCEARE SHOWN AS 8" MAX. AND
 6" MIN. RESPECTIVELY.THESE DIMENSIONS
 SHOULD BE 6" MAX. AND 8" MIN. AS SHOWN
 ON FIGURE 31.
  
 8)FL ACC CODE 4.16.4WATER CLOSET
 GRAB BARS.THE DIMENSIONS AN SHEET A-3,
 FOR THE GRAB BAR BEHIND THE W.C., SHALL
 BE AMENDED TO SHOW 12" MIN. BETWEEN THE
 CENTER LINE OF THE W.C. AND THE ENDS OF
 THE GRAB BAR AS SHOWN ON FIGURE 29.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUERIES PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499