| Date |
Text |
| 2002-03-15 00:00:00 | BUILDING PLAN REVIEW |
| | *******DENIED******* |
| | ROBERT BROWN(561) 659 8096 EXT 8499 |
| | |
| | SBC = STANDARD BUILDING CODE 1997 |
| | SBC*= STANDARD BUILD'G CODE (CITY AMEND) |
| | FL ACC CODE = FLORIDA ACCESSIBILITY CODE |
| | |
| | FOR CONSISTENCY, THE FOLLOWING COMMENTS |
| | ARE NUMBERED AS PER THE BUILDING PLAN |
| | REVIEW OF 1/30/02: |
| | |
| | 1) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 2) IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY, PLANS STAMPED BY THEM AND |
| | COPY OF RECEIPT SUBMITTED TO CITY OF |
| | WEST PALM BEACH BUILDING DEPARTMENT, |
| | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| | |
| | 3) --PROVISO--SBC* 104.1.1A SEPARATE |
| | ROOFING PERMIT APPLICATION IS REQUIRED. |
| | |
| | 4) --PROVISO--SBC* 104.1.1A SEPARATE |
| | SHUTTER AND WINDOW/DOOR PERMIT |
| | APPLICATION IS REQUIRED. |
| | |
| | 5) SBC* 104.2.1SHEET A1, FLOOR PLAN |
| | AND COOLER SECTION.THIS COMMENT HAS |
| | NOT BEEN ADDRESSED.THERE IS STILL NO |
| | DESCRIPTION OF THE WALL CONSTRUCTION |
| | AROUND THE NEW CHILLER.ALSO, THE |
| | 'DUMPSTER DETAILS' DO NOT REFLECT THE |
| | DUMPSTER LAYOUT OR THE VERTICAL REBAR |
| | SPACING INDICATED ON THE FLOOR PLAN. |
| | |
| | 6) SBC 2405.2.1.SAFETY GLASS.THIS |
| | COMMENT HAS NOT BEEN ADDRESSED.THE |
| | DOOR SCHEDULE AND FRONT ELEVATION HAVE |
| | NOT BEEN ADEQUATELY ANNOTATED TO SHOW |
| | COMPLIANCE WITH THE REQUIREMENT FOR |
| | 'SAFETY GLASS'. |
| | |
| | 7) FL ACC CODE 4.1.5SHEET C1, |
| | ACCESSIBLE TOILET.ON THE PLAN AND |
| | ELEVATION, THE GRAB BAR ADJACENT THE W.C |
| | SHALL BE MIN. 42" LONG (NOT 36").THE |
| | GRAB BAR BEHIND THE W.C. MAY BE MIN. 36" |
| | LONG.ON THE W.C. ELEVATION, THE 18" |
| | DIMENSION BETWEEN THE WALL AND THE W.C. |
| | CENTRELINE IS INCORRECTLY SHOWN AS BEING |
| | MEASURED BETWEEN THE WALL AND THE W.C. |
| | FLUSH TANK.CORRECT THE DIMENSION TO |
| | SHOW COMPLIANCE WITH FIGURES 28 AND 29. |
| | |
| | 8) FL ACC CODE 5.0SEATING.THE |
| | MAXIMUM TABLE HEIGHT AND MINIMUM KNEE |
| | CLEARANCE FOR THE ACCESSIBLE SEAT SHALL |
| | BE IN ACCORDANCE WITH FL ACC CODE 4.32.3 |
| | AND 4.32.4 |
| | |
| | **QUOTE PERMIT# ON ALL CORRESPONDENCE** |
| | |
| | END OF REVIEW COMMENTS |
| | THE CODE REFERENCES GIVE ADDITIONAL INFO |
| | IF YOU HAVE ANY QUERIES PLEASE CALL: |
| | ROBERT BROWN(561) 659 8096 EXT 8499 |