| Date |
Text |
| 2002-01-24 00:00:00 | *************BUILDING DENIED************ |
| | |
| | 1) IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY, PLANS STAMPED BY THEM AND |
| | COPY OF RECEIPT SUBMITTED TO CITY OF |
| | WEST PALM BEACH BUILDING DEPARTMENT, |
| | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| | |
| | 2) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 3) FL ENERGY CODE COMPLIANCE FORM MUST |
| | BE SIGNED AND DATED BY THE OWNER OR |
| | AGENT. |
| | |
| | 4) CORRECT ENERGY FORM TO INDICATE THE |
| | RAISED WOOD FLOOR AND R-11 INSULATION |
| | THAT IS REQUIRED. |
| | |
| | 5) INDICATE R-11 INSULATION AT RAISED |
| | WOOD FLOOR SYSTEM ON THE PLANS. |
| | |
| | 6) PROVIDE CRAWL SPACE VENTILATION PER |
| | 97 SBC 1804.6.2.1. |
| | |
| | 7) INDICATE STEM WALL BOND BEAM WITH |
| | HORIZONTAL REINFORCEMENT. INDICATE THE |
| | SIZE AND SPACING OF THE VERTICLE |
| | REINFORCEMENT BETWEEN THE BOND BEAM AND |
| | THE FOOTING. |
| | |
| | 8) PROVIDE ATTIC ACCESS. 97 SBC 2309.6 |
| | |
| | 9)PROVIDE (2) CURRENT AND COMPLETE |
| | COPIES OF SBCCI OR METRO-DADE PRODUCT |
| | APPROVALS FOR: |
| | - HARDY BOARD SIDING |
| | - FRENCH DOORS |
| | - ROOFING MATERIAL (OR SUBMIT UNDER A |
| | SEPARATE PERMIT) |
| | |
| | 10) PROVIDE AN UPDATED PRODUCT APPROVAL |
| | (SBCCI REPORT NO. 9756A) FOR STORM |
| | PANELS. PROVIDE AN INSTALLATION SCHEDULE |
| | AND KEY PLAN. INDICATE THE TYPE ANCHORS |
| | THAT WILL BE USED ON SHEET 4 OF THE |
| | STORM PANEL DRAWINGS. |
| | |
| | 11) PROVIDE A DOOR WITH A 29" CLEAR |
| | OPENING TO TOILET AS REQUIRED BY 97 FL |
| | ACCESSIBILITY CODE. |
| | |
| | 12) PROVIDE A TYPICAL DETAIL OF EXTERIOR |
| | BEARING WALL WINDOW/DOOR OPENINGS, |
| | INDICATING HEADER SIZE, # OF JACKS, |
| | STRAPPING, ETC. |
| | |
| | 13) INDICATE THE INTERIOR BEARING WALL |
| | AND THE SIZE HEADER AT THE OPENING TO |
| | THE MASTER BEDROOM. PROVIDE TYPICAL |
| | INTERIOR BEARING WALL DETAIL, INDICATING |
| | CONTINOUS LOAD PATH FROM FOOTER TO ROOF. |
| | OR INDICATE IF GIRDER TRUSS WILL BE USED |
| | IN PLACE OF INTERIOR BEARING WALL. |
| | INDICATE ADEQUATE LOAD PATH TO RESIST |
| | UPLIFT FOR GIRDER TRUSS. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)659-8096 EXT.8202 |