Plan Review Notes
Plan Review Notes For Permit 02010564
Permit Number 02010564
Review Stop B
Sequence Number 2
Notes
Date Text
2002-04-02 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THE BUILDING PLAN
 REVIEW OF 1/22/02:
  
 1) CONTRARY TO THE LEAR ASSOCIATES
 RESPONSE LETTER RECEIVED 3/13/02 THIS
 COMMENT HAS NOT BEEN ADDRESSED.A
 RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) THE SWITCH FROM STANDARD BUILDING
 CODE 1997 TO FLORIDA BUILDING CODE 2001
 IS NOTED. FOR SPRINKLERED BUILDINGS, FBC
 TABLE 1004, NOTE 20, ALLOWS DEAD-END
 CORRIDORS UPTO 50FT (COMPARED TO MAXIMUM
 20FT IN SBC).NO FURTHER ACTION REQ'D.
  
 3) FBC 11-4.1.2(1)ACCESSIBLE ROUTE.
 THIS COMMENT HAS NOT BEEN PROPERLY
 ADDRESSED.ANNOTATE THE PLANS TO
 DEMONSTRATE COMPLIANCE WITH THE
 REQUIREMENTS FOR AT LEAST ONE ACCESSIBLE
 ROUTE, TO THE ENTRANCE, FROM ACCESSIBLE
 PARKING, PUBLIC SIDEWALKS AND PUBLIC
 TRANSPORT,INDICATING CURB RAMPS, CHANGES
 IN DIRECTION ETC. (REFER TO THE CODE FOR
 FULL REQUIREMENTS).
  
 4) FBC 11-4.1.3(10)DRINKING FOUNTAIN.
 THIS COMMENT HAS NOT BEEN PROPERLY
 ADDRESSED.THE SPOUT HEIGHT AND
 CLEARANCES AT THE DRINKING FOUNTAIN, IN
 ACCORDANCE WITH FIG 27, SHALL BE SHOWN
 ON SHEET A-2.
  
 5) FBC 11-4.35.4THIS COMMENT HAS NOT
 BEEN PROPERLY ADDRESSED. THE PLANS SHALL
 BE ANNOTATED TO SHOW THE BENCH MOUNTING
 HEIGHT, REQUIRED TO BE BETWEEN 17" AND
 19" ABOVE FINISHED FLOOR.
  
 8) FBC* 104.2.1.2NEW FLOOR SLAB.THE
 PLANS STILL DO NOT SHOW CONTINUITY OF
 REINFORCEMENT BETWEEN THE NEW SLAB AND
 THE ADJACENT EXISTING CONCRETE USING
 DOWEL BARS OR SIMILAR.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUERIES PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499


Account Summary | Usage Policy | Privacy Policy