| 2002-01-09 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT # 01121705 | | | 828 W LAKEWOOD RD | | | O/B LAZO, CARDID | | | TEL: 963-0357 | | | | | | SBC= 1997 STANDARD BUILDING CODE | | | SBC*= AMENDMENTS/ STANDARD BUILDING CODE | | | | | | 1)- SBC 104.2.1 SEE ATTACHMENT FOR QAULI | | | TY OF PLANS. | | | 2)- ATTACHED ARE SOME PRESCRIPTIVE RE- | | | QUIREMENTS FOR DESIGN. PLANS SHALL RE- | | | FLECT THIS ADDITIONAL INFORMATION. | | | STRUCTURAL PLANS WILL INDICATE THE | | | FOLLOWING: | | | FLOOR PLAN, | | | WALL ELEVATIONS INDICATE THE WINDOW | | | SIZES, WALL FINISHES, | | | WALL SECTIONS SEE ATTACHMENT, HEADER | | | SIZES, ANCHOR AND STRAPPING REQUIREMENT | | | 3)- SBC 1814.2.4 WALL & FLOOR JOINTS AND | | | PENETRATIONS SHALL BE MADE WATERTIGHT | | | USING APPROVED METHODS ANS MATERIALS. | | | 4)- 2304.2.5. CLEARENCE BETWEEN WOOD | | | SIDING, SHEATHING SHALL BE NOT LESS THAN | | | 6" ABOVE THE NATURAL GRADE. | | | 5)- OWNER WILL TAKE THE PLANS TO THE | | | COUNTY FOR IMPACT FEE ASSESSMENT. | | | 6)- PRODUCT APPROVAL REPORTS REQUIRE | | | 2 COPIES. | | | 7)- THE WINDOW REPORT SUBMITTED HAS NOT | | | BEEN TESTED FOR LARGE MISSLE IMPACT | | | RESISTANCE, STORM SHUTTERS SHALL BE REQU | | | IRED SUBMIT 2 COPIES OF PRODUCT TESTING | | | REPORTS. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561)659-8096X8412 |
|