| 2002-02-07 00:00:00 | THIS BUILDING WILL BE A THRESHOLD |
| | BUILDING AS DEFINED IN F.S. 553 AND |
| | WILL REQUIRE A THRESHOLD INSPECTION |
| | PLAN AND A THRESHOLD INSPECTOR. |
| | CONTACT DON NEELY, ASSISTANT BUILDING |
| | OFFICIAL, FOR MORE INFORMATION. |
| | 561-659-8096 X 8219. |
| | |
| | BEFORE A PERMIT TO CONSTRUCT MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY FOR THE CITY, THE |
| | PERMIT PLANS STAMPED BY THAT OFFICE, |
| | AND A COPY OF THE PAID RECEIPT ATTACHED |
| | TO THE PERMIT APPLICATION. |
| | |
| | AT TIME OF PERMIT APPLICATION THE |
| | FOLLOWING ITEMS MUST ACCOMPANY THE |
| | APPLICATION: (THREE COPIES OF EACH FOR |
| | THRESHOLD BUILDINGS) |
| | |
| | A RECENT SIGNED AND SEALED PROPERTY |
| | SURVEY. |
| | |
| | ENERGY CODE CALCULATIONS |
| | |
| | THREE COMPLETE SETS OF WORKING DRAWINGS |
| | |
| | CODE COMPLIANCE NOTES: |
| | |
| | THE TOWER/CUPOLA MUST COMPLY WITH SBC |
| | 1517.5.1.2.1. SINCE PORTIONS OF IT WILL |
| | BE MORE THAN 25' ABOVE THE ROOF AND |
| | PORTIONS IN CROSS SECTION WILL EXCEED |
| | 200 SQUARE FEET. EITHER OF THE |
| | CONDITIONS REQUIRE COMPLIANCE WITH THE |
| | CODE SECTION. |
| | |
| | SHEET A7.1, PROVIDE DETAILS OF |
| | CONSTRUCTION FOR THE METAL STUD FRAMING |
| | INCLUDING CONNECTIONS.SEE SBC 104.2. |
| | |
| | SHEET A8.1 SECTION (3), THE VENTED |
| | SCREED IS SHOWN ON THE BOTTOM OF THE |
| | SUB-FASCIA, HOW IS THIS FUNCTIONAL? |
| | |
| | SHEET A8.1 SECTION (1) THE GABLE END IS |
| | SHOWN AS TYPE VI CONSTRUCTION. (WOOD) |
| | SBC TABLE 600 TYPE V CONSTRUCTION IS |
| | REQUIRED TO BE NON-COMBUSTIBLE.SEE |
| | TABLE 600 TITLE LINES "EXTERIOR |
| | BEARING, (AND NON-BEARING) WALLS AND |
| | GABLE ENDS OF ROOF." |
| | |
| | PROVIDE A CEILING CONSTRUCTION DETAIL |
| | FOR THE CUPOLA.SBC 104.2. |
| | |
| | NOTE THAT THIS IS A "PLAN REVIEW" AND |
| | NOT A PERMIT APPLICATION.PERMIT |
| | APPLICATIONS RECEIVED ON OR AFTER MARCH |
| | 1, 2002 WILL BE SUBJECT TO REVIEW FOR |
| | CONFORMANCE WITH THE 2001 FLORIDA |
| | BUILDING CODE WHICH MAY HAVE DIFFERENT |
| | REQUIREMENTS. |