| 2002-03-22 00:00:00 | DENIED |
| | REFERENCE: SPC-94 - SGC-97 - FACBC-97 |
| | |
| | 1) SHTS A5.01/A5.02/M3.1/M3.2 FROM PRE- |
| | VIOUS REVIEW, PLEASE SHOW CLEAR FLOOR |
| | SPACE FOR ALL HDCP FIXTURES. LAV SHALL |
| | BE CENTERED ON 30X48 CLEAR FLOOR SPACE. |
| | 2) SHTS A5.01/A5.02/M3.1/M3.2 DOOR SHALL |
| | NOT SWING INTO CLEAR FLOOR SPACE OF HDCP |
| | FIXTURES. FACBC SEC 4.17.5 |
| | 3) SHT M2.2 GAS PERMIT APPLICATION RE- |
| | QUIREMENTS #2, WELDERS CERTIFICATION AND |
| | WELDING PROCEDURE REQUIRED BEFORE GAS |
| | PERMIT ISSUED. |
| | 4) SHT M2.2 GAS PERMIT APPLICATION RE- |
| | QUIREMENTS #7 GAS PRESSURE NOT DELIVERED |
| | AT 7" OF WATER COLUUM BUT 12" TO 14". |
| | PLEASE CHECK WITH GAS PROVIDER. |
| | 5) SHT M2.2 GAS PERMIT APPLICATION RE- |
| | QUIREMENTS #9 UNABLE TO FIND SHTS SM-1 |
| | AND SKM-4 AND MANUFACTURE CUT SHEETS. |
| | THEY WERE NOT ON BLUE PRINTS, VENDOR EQ- |
| | UIPMENT MANUAL OR PROJECT MANUAL. PLEASE |
| | INDICATE WHERE I MIGHT FIND THESE SHEETS |
| | 6) SHT M2.2 COLS B/15-17-19-21. AIR GAP- |
| | 1 FITTINGS ARE FOR CONDENSATE LINES. |
| | CONDENSATE SHALL NOT DRAIN INTO WASTE |
| | AS SHOWN ON CIVIL PLANS. ALL CONDENSATE |
| | SHALL DRAIN TO STORM OUTSIDE BLDG. |
| | PLEASE GIVE DETAIL OF ALL CONDENSATE |
| | TYING INTO STORM WITH A RELIEF VENT ON |
| | CONDENSATE AS IT EXITS BLDG. |
| | 7) SHTS M3.1/M3.2/M3.3 FROM PREVIOUS RE- |
| | VIEW, PLEASE SHOW DETAIL OF CONDENSATE |
| | TYING INTO STORM OUTSIDE BLDG. WITH RE- |
| | LIEF VENT ON CONDENSATE AS IT EXITS BLDG |
| | 8) SHT M3.3 OVER FLOW FROM REFRIGATION |
| | EQUIPMENT ON ROOF AS INDICATED IN RES- |
| | PONCE SHALL DRAIN TO STORM NOT SANITARY |
| | AS INDICATED. PLEASE SHOW OVERFLOW TYING |
| | INTO STORM OUTSIDE BLDG. |
| | 9) PER SPC TABLE 407 AN EMERGENCY SHOWER |
| | IS REQUIRED. THIS IS A NEW COMMENT. |
| | 10) WORK SHEET FROM RODNEY COMPO ENVIRON |
| | MENTAL COMPLIANCE STILL REQUIRED FOR |
| | SAND INTERCEP. & DILUTION TANK BEFORE |
| | ISSUANCE OF PERMIT. |
| | |
| | |
| | REVIEW BY KEN STEVENS |