| 2002-03-18 00:00:00 | TRUSS ENGINEERING | | | | | | 1) TRUSS ENGINEERING TO BE REVIEWED BY | | | THE DESIGN PROFESSIONAL BEFORE SUBMITTAL | | | TO THE BUILDING DEPARTMENT. | | | 2) ALL PRODUCTS SPECED OUT ARE SEMCO | | | WHICH ARE OUT OF BUSINESS, USP LUMBER | | | CONNECTORS BOUGHT THEM OUT. | | | 3) THE T-1 2 PLY GIRDER TRUSS HAS AN | | | UPLIFT OF 3155 / 3171 LBS OF UPLIFT. THE | | | ARCH SHEET A-6 INDICATES A SECTION | | | 12/A7 WHICH USES A SEMCO RTP 18824, | | | THE NOTE ADDING A SECOND STRAP WILL | | | INCREASE UPLIFT BUT WILL STILL BE SHORT | | | IN RESISTANCE. | | | | | | CALLED ARCH FIRM SPOKE TO DAVID MC COY | | | ABOUT THE SITUATION. |
|