2002-03-22 00:00:00*************BUILDING UNSAT*************
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) THE DOORS TO THE DEN ON THE ALAMANDA
 MODEL ARE REQUIRED TO HAVE BOTH LEAFS
 ACTIVE TO COMPLY WITH FAIR HOUSING.
  
 4) THE FIRE RATED DOORS BETWEEN THE
 UNITS AND THE GARAGES ARE REQUIRED TO
 HAVE APPROVED CLOSERS PER 97 SBC SECT.
 705.1.3.5.
  
 5)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - DOUBLE OUTSWING FRENCH DOORS WITH
 SIDELITES ON EACH SIDE (SALES OFFICE)
 - ARCHED WINDOWS AS SHOWN ON PLANS (THE
 PRODUCT APPROVAL SUBMITTED IS FOR CIRCLE
 TOP WINDOWS,THIS IS NOT THE WINDOWS THAT
 ARE INDICATED ON THE PLANS)
  
 6) THE SUBMITTAL FOR THE BALCONY RAIL
 DETAIL IS FOR A SCREEN ROOM. PLEASE
 SUBMIT SHOP DRAWINGS FOR THE GUARDRAILS
 AT THE 2ND FLOOR COVERED PORCHES PRIOR
 TO INSTALLING.
  
 7) PROVIDE A KEY PLAN AND INSTALLATION
 SCHEDULE FOR THE STORM PANELS OR SUPPLY
 THE REQUIRED INFORMATION UNDER A
 SEPARATE PERMIT AT A LATER DATE. THE
 MARKING OF THE OPENINGS ON THE PLANS IS
 NOT ACCEPTABLE. A SEPARATE KEY PLAN IS
 WHICH IS CLEAR AND READABLE IS REQUIRED.
 REMOVABLE STORM PANELS CAN NOT BE USED
 ABOVE THE GROUND FLOOR. IMPACT RESISTANT
 GLAZING OR PERMANENTLY AFFIXED
 PROTECTIVE DEVICES SHALL BE INSTALLED.
 SEE ATTACHED.
  
 8) PROVIDE WINDOW, DOOR AND GARAGE DOOR
 BUCK FASTENING DETAILS.
  
 9) DETAILS 13 AND 23 ON A-11 ARE
 MISLABELED AS A-17. PLEASE CORRECT.
  
 10) DETAIL 23 ON A-11 MUST INDICATE THAT
 ONE HOUR TENANT SEPARATION IS MAINTAINED
 TO THE UNDERSIDE OF THE ROOF SHEATHING.
  
 11) THE 9.5" STAIR TREAD DIMENSION ON
 A-7 SHOULD BE EXCLUSIVE OF THE NOSING.
 HOWEVER IT APPEARS TO INCLUDE THE
 NOSING AS DRAWN. SEE 97 SBC SECT.
 1007.3.1 AND 1007.3.2.
  
 12)THE BUILDING OFFICIAL WAS UNAVAILABLE
 AT TIME OF THIS REVIEW. IN ORDER TO
 EXPEDIATE THE REVIEW PROCESS I WILL
 REVIEW A COPY OF THE LETTER REQUESTING A
 TEMPORARY SALES OFFICE WITH HIM WHEN HE
 RETURNS. THIS WILL ALLOW YOU TO ADDRESS
 THE OTHER ISSUES IN THE INTERIM.
  
 TRUSSES
  
 1) THE PA23 CONNECTOR LISTED IN DETAIL
 19 ON A-11 FOR TRUSS GT2, IS A PURLIN
 ANCHOR AND IS NOT DESIGNED TO BE USED AS
 A TRUSS ANCHOR. PLEASE CORRECT.
  
 2) THERE IS NO CONNECTOR OR CONNECTION
 DETAIL INDICATED FOR TRUSS GT1. DETAIL
 32 ON A-11 INDICATES THE ATTACHMENT OF
 THE WOOD FRAME WALL TO THE MASONRY.
  
 3) THE TRUSS DRAWINGS, LETTERS FROM THE
 TRUSS ENGINEER AND DETAILS REQUIRE THE
 TRUSS ENGINEERS SIGNATURE, EMBOSSED SEAL
 AND THE DATE ON EACH SHEET.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202