Plan Review Notes
Plan Review Notes For Permit 01121475
Permit Number 01121475
Review Stop B
Sequence Number 1
Notes
Date Text
2002-02-07 00:00:00*************BUILDING UNSAT*************
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) BUILDINGS, WHICH THE PERMITS ARE
 APPLIED FOR AFTER MARCH 1,2002, ARE
 REQUIRED TO BE DESIGNED TO COMPLY WITH
 THE 2001 FLORIDA BUILDING CODE. THIS IS
 REQUIRE TO BE LISTED ON THE PLANS.
  
 4) TEMPORARY SALES OFFICE IN GARAGE OF
 MODEL MUST BE APPROVED BY THE PLANNING
 AND ZONING DEPT. AND THE BUILDING
 OFFICIAL. SALES OFFICE MUST MEET
 ACCESSIBILITY REQUIREMENTS, INCLUDING
 ACCESSIBLE TOILET FACILITIES. A
 CONDITIONAL CERTIFICATE OF OCCUPANCY
 WILL BE REQUIRED BEFORE THE OFFICE CAN
 BE OPENED. THE FINAL C.O. FOR THE
 RESIDENCE WILL BE ISSUED AFTER THE
 TEMPORARY COMPONENTS HAVE BEEN REMOVED
 AND THE PERMANENT COMPONENTS ARE
 INSTALLED. YOU MUST SUBMIT A LETTER FROM
 ONE OF THE PRINCIPLES WITH THE COMPANY
 (NOTARIZED OR WITH CORPORATE SEAL) TO
 THE BUILDING OFFICIAL WITH YOUR REQUEST,
 INDICATING THE LENGTH OF TIME THIS
 CONDITION WILL EXIST, THAT THE TEMPORARY
 WALLS,ETC. WILL BE REMOVED AND THE
 GARAGE DOORS,ETC. WILL BE INSTALLED.
 TEMPORARY EXTERIOR WALLS AND DOORS MUST
 MEET WINDLOAD REQUIREMENTS AND MISSLE
 IMPACT PROTECTION IS REQUIRED.
  
 5) THE IMPORTANCE FACTOR ON SHEET C-1 IS
 INCORRECT.
  
 6) DETAIL 2B ON SHEET A-2 REFERENCED FOR
 F-10 ON THE FOOTING SCHEDULE DOES NOT
 SHOW THE SHOWER RECESS.
  
 7) THE 97 SBC CLASSIFIES DOORS AS 3-HOUR
 1-1/2-HOUR, 1-HOUR, 3/4-HOUR OR
 20-MINUTES, NOT BY LETTER LABELS.
 INDICATE ON PLANS THE ONE YOU ARE
 SPECIFYING FOR RATED DOOR AT GARAGE.
  
 8) THE BEDROOM WINDOWS MUST COMPLY WITH
 SECTION 1005.4 FOR EMERGENCY EGRESS.
 PLEASE PROVIDE THE CLEAR OPENING SIZES
 FOR THE 8'X 5' H.S. AND THE SH 34+4
 WINDOWS.
  
 9) PROVIDE DETAILS FOR THE GUARDRAIL AT
 THE 2ND FLOOR FOYER.
  
 10) THE SOIL REPORT RECOMMENDS THE
 EXTERIOR FOUNDATIONS BEAR 18" BELOW
 ADJACENT OUTSIDE FINAL GRADE. THE PLANS
 INDICATE 16" FOOTINGS.
  
 11) THE EXTERIOR WALL SECTIONS ON A-8
 INDICATE 6" MIN. ABOVE GRADE AND THE
 97 SBC REQUIRES BOTTOM OF FOOTINGS TO
 BE A MINIMUM OF 12" BELOW FINISH GRADE.
 THIS CAN NOT BE ACCOMPLISHED WITH 16"
 FOOTERS.
  
 12) THE ORNAMENTAL PATTERNS ON THE
 GUARDRAILS AT THE VERANDAS ARE REQUIRED
 TO REJECT THE PASSAGE OF A 4" DIAMETER
 SPHERE THROUGH ANY OPENING AND THE
 BOTTOM RAIL SHALL REJECT THE PASSAGE OF
 A 2" DIA. SPHERE PER 97 SBC 1015.3.
 INDICATE THE METHODS THAT WILL BE USED
 TO ATTACH THE GUARDRAILS TO THE
 STRUCTURE.
  
 13) DETAIL 29 ON A-11 APPEARS TO BE IN
 ERROR. SHEET A-9 INDICATES A MASONRY
 COLUMN AT THIS LOCATION. PLEASE CORRECT.
  
 14) DETAILS 16 & 17 ON A-11 ARE MARKED
 INCORRECTLY AS A-16.
  
 15) INDICATE THE RISER AND TREAD
 DIMENSIONS OF THE STAIRS ON THE PLANS.
  
 16) THE DESIGN INFORMATION THAT IS GIVEN
 ON THE DESIGN CERTIFICATION COMPLIANCE
 FORM IS REQUIRED TO BE ON THE PLANS. THE
 SEPARATE FORM WILL NO LONGER BE ACCEPTED
  
 17) INDICATE THE POSITIVE AND NEGATIVE
 WIND PRESSURES FOR EXTERIOR WINDOWS AND
 DOORS ON THE PLANS.
  
 18) THE ELEVATORS ARE REQUIRED TO COMPLY
 WITH ANSI/ASME A17.1 AND ANSI A117.1.
  
 19) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - SINGLE HUNG WINDOWS (ONES SUBMITTED
 WERE EXPIRED)
 - HORIZONTAL SLIDING WINDOWS
 - ARCHED FIXED GLASS WINDOWS
 - RECTANGULAR FIXED GLASS WINDOWS
 - FRENCH DOORS WITH & WITHOUT SIDELITES
 (SALES OFFICE)
  
 20) THE 9606C SBCCI EVALUATION REPORT
 (PRODUCT APPROVAL) TO ACCOMPANY THE
 DRAWING FOR THE CLOPAY GARAGE DOOR.
  
 21) THE SITE SPECIFIC PRODUCT APPROVALS
 FOR THE FRONT DOOR ARE REQUIRED TO BE
 ORIGINALS; SIGNED, SEALED AND DATED BY
 THE ENGINEER FOR THE PRODUCT AND BY THE
 DESIGNER OF THE STRUCTURE INTO WHICH IT
 WILL BE INSTALLED.
  
 22) PROVIDE KEY PLAN AND INSTALLATION
 SCHEDULE FOR STORM PANELS. INDICATE ON
 THE DRAWINGS THE MOUNTING ANCHORS THAT
 WILL BE USED.
  
 23)SHOW COMPLIANCE WITH FAIR HOUSING ACT
 ALL BUILDING ENTRANCES ARE REQUIRED TO
 BE ACCESSIBLE AND BE ON AN ACCESSIBLE
 ROUTE.
 - THE PRIMARY ENTRANCE DOOR MUST
 MEET THE REQUIREMENTS FOR ACCESSIBLE
 DOORS (32" CLEAR OPENING,LOW OR NO
 THRESHOLD 3/4"MAX.,HARDWARE COMPLYING
 WITH ANSI 4.13.9, ETC.)
 - DOORS WITHIN UNIT MUST BE USEABLE
 DOORS. MUST PROVIDE AT LEAST A 31-5/8"
 CLEAR OPENING.
 - INDICATE THE SIZE OF MASTER BATHROOM
 DOOR ON PLANS.
 - THE WALK-IN CLOSET IN BEDROOM #3 OF
 UNIT "D" REQUIRES A DOOR WITH A 32"
 NOMINAL OPENING (2'10" DOOR).
 - BOTH LEAFS OF THE DOUBLE DOOR AT DEN
 IN UNIT "D" ARE REQUIRED TO BE ACTIVE.
 - THE WALK-IN CLOSET IN BEDROOM #3 OF
 UNIT "C" REQUIRES A 2'10" DOOR.
 - THE STEP UP SHOWN AT THE PRIMARY ENTRY
 DOOR AND AT GARAGE ON SECTION A-A AND
 B-B ARE NOT PERMITTED.
 - LIGHT SWITCHES, ELECTRICAL OUTLETS,
 THERMOSTATS AND CONTROLS SHALL BE IN
 ACCESSIBLE LOCATIONS.
 - INDICATE MINIMUM CLEAR FLOOR SPACES AT
 FIXTURES AND APPLIANCES IN THE KITCHEN.
 - IN UNITS "A" AND "D", 40" CLEARANCE
 MUST BE MAINTAINED BETWEEN THE FACE OF
 THE KITCHEN ISLAND AND ALL OPPOSING
 FEATURES.
 - THE FAIR HOUSING ACT REQUIRES THE
 BATHROOMS TO BE DESIGNED TO COMPLY
 WITH SPECIFICATION A OR B BATHROOMS.
 INDICATE WHICH ONE WILL BE USED AND SHOW
 COMPLIANCE WITH DESIGN METHOD SELECTED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202