2002-04-15 00:00:00*************BUILDING UNSAT*************
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) SUBMIT SHOP DRAWINGS FOR GUARDRAIL AT
 2ND FLOOR COVERED PORCH FOR APPROVAL
 PRIOR TO INSTALLATION.
  
 4)THE REAR ELEVATION SHOWS THE 2ND FLOOR
 GUARDRAIL WITH A 4" SPACE BETWEEN THE
 BOTTOM RAIL AND THE FLOOR. THE CODE
 REQUIRES THAT THE BOTTOM RAIL REJECT THE
 PASSAGE OF A 2" SPHERE. PLEASE CORRECT.
  
 5) SECTION B-B ON SHEET A7 SHOWS A 9.5"
 TREAD EXCLUSIVE OF THE NOSING WITH A
 7.37" RISER AND THE STAIR DETAIL (1/A7)
 NOTES 10"TREAD EXCLUSIVE OF NOSING WITH
 A 7.22" RISER. PLEASE CORRECT.
  
 6) THE FRONT ELEVATION ON A5 NOTES A
 CEMENTITOUS FINISH OVER CONCRETE BLOCK
 CONSTRUCTION AT THE EXTERIOR WALL OF THE
 2ND FLOOR BEDROOM #3, WHICH IS WOOD
 FRAME. PLEASE CORRECT AND INDICATE THE
 EXTERIOR FINISH THAT WILL BE APPLIED TO
 THIS WALL. (WIRE LATH AND STUCCO?)
  
 7) INDICATE FIREBLOCKING WHERE THE WOOD
 EXTERIOR WALL AND CEILING INTERSECT AT
 THE GABLE END OF 2ND FLOOR BEDROOM #3 ON
 SECTION A-A ON SHEET A7.
 INDICATE THAT THE GABLE ENDWALL WILL
 BE BALLOON FRAMED TO THE VAULTED CEILING
 DIAPHRAM.
  
 8) SHEET A1 IS MISSING THE FOOTING
 DESIGNATIONS. THE COLUMN AND FOOTING
 MARKS THAT TIE TO THE SCHEDULES ARE ALSO
 MISSING. PLEASE CORRECT.
  
 9) PROVIDE (2) PRODUCT APPROVALS, KEY
 PLANS AND INSTALLATION SCHEDULES
 INDICATING THE SPECIFIC TYPES OF ANCHORS
 TO BE USED FOR STORM PANELS.
 IMPACT GLAZING OR PERMANENTLY AFFIXED
 PROTECTIVE DEVICES ARE REQUIRED ABOVE
 THE FIRST LEVEL. PERMANENTLY AFFIXED
 PROTECTIVE DEVICES REQUIRE THE WRITTEN
 APPROVAL OF THE BUILDING OFFICIAL.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202