Text |
| 2002-06-12 00:00:00 | DENIED | | | | | | ADDITIONAL INFORMATION IS REQUIRED ON | | | THE SHOP DRAWINGS FOR THE SECOND FLOOR | | | GUARDRAILS. | | | | | | 1) INDICATE THE HEIGHT OF THE GUARDRAIL | | | ON THE DRAWINGS. THE MINIMUM REQUIRED | | | HEIGHT IS 42". SEE FBC SEC.1015.2. | | | | | | 2) INDICATE THE ATTACHMENT AND FASTENERS | | | THAT WILL BE USED. FBC SEC. 1015.4 | | | | | | 3) INDICATE ON THE DRAWINGS THE LOADS | | | THAT THE GUARDRAIL SYSTEM IS CAPABLE OF | | | RESISTING. SEE FBC SEC 1608.2.2. | | | | | | 4) IN ADDITION TO THE ORNAMENTAL PATTERN | | | THAT RESISTS THE PASSAGE OF A 4-INCH | | | DIAMETER SPHERE A BOTTOM RAIL OR CURB IS | | | REQUIRED THAT WILL REJECT THE PASSAGE OF | | | A 2-INCH DIAMETER SPHERE. PLEASE | | | INDICATE THIS ON THE PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|