2003-04-22 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 01120694
 ADD: 2901 TUXEDO DRIVE
 CONT: E. O. KOCH
 TEL: (561)998-0955
 1997 SBC= 1997 STANDARD BUILDING CODE
  
 REVISION: DENIED
  
 THIS BUILDING WAS DESIGNED UNDER THE
 1997 STANDARD BUILDING CODE.THE CITIES
 INTERPRETATION FOR THE IMPLEMENTATION
 OF HURRICANE MISSLE IMPACT PROTECTION
 STANDARD AUSUST 1,2001 WAS IN AFFECT.
 THE STANDARD ALLOWS FOR SITE SPECIFIC
 ENGINEERING WHEN A MODEL CODE EVALUATION
 & COMPLIANCE REPORT IS NOT AVAILABLE.
  
 A COPY OF THE SITE SPECIFIC ENGINEERING
 FORM IS ATTACHED. SEE QUESTION 17 B AND
 ALTERNATE METHOD # 2. BOTH THE CERTIFICA
 TE OF COMPLIANCE AND INSTALLATION AFFI-
 DAVIT ARE TO BE ON THE APPROVED FORMS
 PROVIDED BY THE CITY OF WEST PALM BEACH.
  
 THE ENGINEER THAT TESTED THE OVERHEAD
 DOOR FILLS OUT THE REQUIRED INFORMATION
 ON THE LEFT SIDE OF THE FORM, AND SIGNS
 AND SEALS THE BOTTOM LEFT ATTESTING TO
 THE TESTING OF THE PRODUCT.
 THE ENGINEER OF RECORD FILLS OUT THE
 RIGHT SIDE, BUCK ATTACHMENT ENCLUDED.
 THE DESIGN PROFESSIONAL SEALS THE RIGHT
 SIDE OF THE FORM ATTESTING THIS PRODUCT
 WILL WORK IN THIS STRUCTURE.
  
 A SEPERATEPERMIT WILL BE REQUIRED
 FOR THE OVERHEAD DOORS. SEE BOTTOM OF
 PAGE 7 OF STANDARD. WHEN PRODUCT APPROVA
 LS NOR ENGINEERED DRAWING ARE SUBMITTED
 WITH THE PERMIT APPLICATION, THEN A
 SEPERATE PERMIT WILL BE REQUIRED.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)659-8096 X 8412
 FAX: (561)659-8026