| Plan Review Notes For Permit 01120445 |
| Permit Number |
01120445 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2002-01-30 00:00:00 | APPROVED WITH PROVISO: | | | | | | 1-PROVIDE PRODUCT APPROVAL FOR ROUND | | | WINDOW WITH LEGIBLE DRAWINGS. | | | 2-PRODUCT APPROVAL FOR ROUND WINDOWS TO | | | SHOW SQUARE FRAME FOR ROUND WINDOW AS | | | SPECIFIED BY ENGINEER OR ENGINEER OF | | | RECORD TO PROVIDE COMPLETE FRAMING | | | DETAILS AND SPECIFICATIONS. | | | 3-SEE STORM PANELS APPROVED DRAWINGS FOR | | | ANCHOR TYPE AND SPACING TO BE USED. | | | 4-REVISE ROOF FRAMING PLAN AS REQUIRED. | | | HOW ARE ROOF TRUSSES ATTACHED TO THE | | | WALL?. CONNECTOR SPECIFIED IS TO | | | ATTACH STUD TO TOP PLATE. | | | -REVISE UPLIFT LOADS SPECIFIED FOR | | | SIMPSON LTS16 STRAP. SEE SIMPSON | | | CATALOGUE AND REVISE ACCORDING TO | | | NAILING AND STRUCTURAL WOOD USED. | | | SEE COMMENTS ON SHEET 2 OF 2. | | | 5-SEE PLANS FOR ADDITIONAL COMMENTS. |
|