2002-01-17 00:00:00************BUILDING PROVISO************
  
 1) STRUCTURE IS LOCATED IN AN A8 FLOOD
 ZONE,AN ELEVATION CERTIFICATE IS
 REQUIRED.
  
 2) RESUBMIT STORM PANEL INFORMATION WITH
 MASTERED DRAWINGS. THE ONES SUBMITTED
 WERE VALID FOR ONE PERMIT ONLY.
  
 3) PROVIDE UPDATED PRODUCT APPROVALS FOR
 FRONT DOOR.
  
 4) SUBMIT CURRENT PRODUCT APPROVALS FOR
 GARAGE DOOR. SBCCI HAS DELETED THE 2015
 PRODUCT EVALUATION REPORT.
  
 5) REVISE THE EXTERIOR CEILING DETAIL ON
 A-1 & A-1B TO COMPLY WITH ASTM C-1063,
 WHICH REQUIRES FASTENERS TO PENETRATE
 1-3/4" INTO HORIZONTAL FRAMING MEMBERS.
  
 6) MSATER BEDROOM WINDOWS MUST COMPLY
 WITH 97 SBC 1005.4, FOR EMERGENCY
 ESCAPE AND RESCUE OPENINGS.