Plan Review Notes
Plan Review Notes For Permit 01120352
Permit Number 01120352
Review Stop R
Sequence Number 1
Notes
Date Text
2002-01-16 00:00:00************BUILDING PROVISO************
  
 1) STRUCTURE IS LOCATED IN AN A8 FLOOD
 ZONE, AN ELEVATION CERTIFICATE IS
 REQUIRED.
  
 2) RESUBMIT STORM PANEL INFORMATION WITH
 MASTERED DRAWINGS. THE ONES SUBMITTED
 WERE VALID FOR ONE PERMIT ONLY.
  
 3) PROVIDE UPDATED PRODUCT APPROVAL FOR
 FRONT DOOR.
  
 4) SUBMIT CURRENT PRODUCT APPROVALS FOR
 GARAGE DOOR. SBCCI HAS DELETED THE 2015
 REPORT FOR ABLE GARAGE DOORS.
  
 5) REVISE THE EXTERIOR CEILING DETAIL ON
 A-1 & A-1B TO COMPLY WITH ASTM C-1063,
 WHICH REQUIRES FASTENERS TO PENETRATE
 HORIZONTAL FRAMING MEMBERS 1-3/4".
  
 6) MASTER BEDROOM WINDOWS MUST COMPLY
 WITH 97 SBC 1005.4, FOR EMERGENCY ESCAPE
 AND RESCUE OPENINGS.