| Plan Review Notes For Permit 01120136 |
| Permit Number |
01120136 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2002-02-05 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT # 01120136 | | | 820 RIDGEWOOD DR | | | CONT: GARRETT CONST CORP | | | TEL: 792-6090 | | | SECOND REVIEW | | | | | | SBC= 1997 STANDARD BUILDING CODE | | | | | | 1)- SBC 2304.2.2 ALL POST POLES & | | | COLUMNS SUPPORTING PERMANENT STRUCTURES | | | AND EMBEDDED IN CONCRETE WHICH IS IN | | | CONTACT WITH GROUND SHALL BE APPROVED | | | PRESERVATIVE-TREATED WOOD SUITABLE FOR | | | GROUND CONTACT USE. | | | | | | 2) SBC 1606.2.6.2 COMPONENTS & CLADDING | | | PRODUCT APPROVALS (2 COPIES) SHALL BE RE | | | QUIRED FOR THE FOLLOWING ITEMS: | | | | | | GARAGE OR OVERHEAD DOORS: OPENING SIZE | | | IS 10'WX 8'H THE REPORT FURNISHED IS | | | MAX AT 9'WX 8H'. | | | ROOF ASSEMBLY TOP SHEET OF REPORT NOT | | | ACCEPTABLE, REPORT IS EXPIRED. | | | REPORT SHALL INDICATE IF THE METAL | | | PANEL ROOFING IS ARCHITECTURAL | | | METAL REQUIRING SOLID SHEATHING OR | | | SBC 1509 OR STRUCTURAL METAL ROOFING | | | COVERED IN SBC 1510 WHICH WILL ALLOW | | | ATTACHMENT THROUGH PURLIN SYSTEM. | | | IF REPORT DOESN'T INDICATE FREQUENCY | | | OF ATTACHMENT MANUFACTURES SPEC | | | SHALL BE REQUIRED. | | | | | | 3)- CONTRACTOR TO SUBMIT PLANS TO COUNTY | | | FOR IMPACT FEE ASSESMENT. | | | | | | 4) PAY RADON FEES, $8.64. |
|