2001-12-11 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01120136
 820 RIDGEWOOD DR.
 CONT: GARRETT CONST. CORP.
 TEL: 792-6090
  
 SBC= STAANDARD BUILDING CODE
 SBC*= AMENDMENTS/ STANDARD BUILDING CODE
  
 DESIGN CERTIFCATION SHEET
 1)- OCCUPANCY: PLANS INDICATE S.F.R.
 CAT. IV.ASCE7-95 TABLE 1-1 MINOR
 STORAGE FACILITY TYPE I NOT IV
  
 2)- BUILDING PARTIALLY ENCLOSED? PLANS
 INDICATE TOTALLY ENCLOSED.
  
 3)- DESIGN FOR 7-95 IS 145 WIND ZONE.
  
 4)- IMPORTANCE FACTOR INCORRECT ASCE
 7.95 TABLE 0.87
  
 5)- ASCE 7-95 EXPOSURE NOT GIVEN, 6.5.3.
 3.1 EXPOSURE CATORIES
  
 6)- SBC 2304.2.2 ALL POST POLES & COL-
 UMNS SUPPORTING PERMANENT STRUCTURES AND
 EMBEDDED IN CONCRETE WHICH IS IN CONTACT
 WITH GROUND SHALL BE APPROVED PRESERVA-
 TIVE-TREATED WOOD SUITABLE FOR GROUND
 CONTACT USE.
  
 7)- SBC 1606.2.6.2 COMPONENTS & CLADDING
 PRODUCT APPROVALS (2 COPIES) SHALL BE
 REQUIRED FORTHE FOLLOWING ITEMS:
 GARAGE OR OVERHEAD DOORS
 EXTERIOR SWING DOORS
 ROOFING ASSEMBLIES
 SBCCI OR DADE COUNTY TEST REPORTS
 ARE REQUIRED.
  
 8)- SBC 1510 STRUCTURAL METAL ROOFING
 SUPPLY MANUFACTURES SPECS FOR APPLCATION
 ALSO SUPPLY INFOR THAT THE ROOF IS
 CAPABLE OF RESISTING LIVE LOADS.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)659-8096 X8412